N2 - Objective: We aimed to assess the therapeutic efficacy of differentially modified soluble receptor for advanced glycation end products (sRAGE) in vivo using vessel ultrasound sonography and to compare the sonography data with those from postmortem histomorphologic analyses to have a practical reference for future clinical applications. Methods: Vessel ultrasound sonography was performed in a sRAGE-treated rat carotid artery balloon injury model at different time points after the surgery, and therapeutic efficacy of different doses of sRAGE produced in Chinese hamster ovary cells and with different N-glycoform modifications were assessed. Results: Vessel ultrasound sonography found that sRAGE produced in Chinese hamster ovary cells with complex N-glycoform modifications is highly effective, and is consistent with our recent findings in the same model assessed with histology. We also found that sonography is less sensitive than histology when a higher dose of sRAGE is administered. Conclusions: Sonograph results are consistent with those obtained from histology; that is, sRAGE produced in Chinese hamster ovary cells has significantly higher efficacy than insect cell-originated sRAGE cells.
AB - Objective: We aimed to assess the therapeutic efficacy of differentially modified soluble receptor for advanced glycation end products (sRAGE) in vivo using vessel ultrasound sonography and to compare the sonography data with those from postmortem histomorphologic analyses to have a practical reference for future clinical applications. Methods: Vessel ultrasound sonography was performed in a sRAGE-treated rat carotid artery balloon injury model at different time points after the surgery, and therapeutic efficacy of different doses of sRAGE produced in Chinese hamster ovary cells and with different N-glycoform modifications were assessed. Results: Vessel ultrasound sonography found that sRAGE produced in Chinese hamster ovary cells with complex N-glycoform modifications is highly effective, and is consistent with our recent findings in the same model assessed with histology. We also found that sonography is less sensitive than histology when a higher dose of sRAGE is administered. Conclusions: Sonograph results are consistent with those obtained from histology; that is, sRAGE produced in Chinese hamster ovary cells has significantly higher efficacy than insect cell-originated sRAGE cells.
UR - http://www.scopus.com/inward/record.url?scp=84909986900&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84909986900&partnerID=8YFLogxK
U2 - 10.1016/j.curtheres.2014.08.001
DO - 10.1016/j.curtheres.2014.08.001
M3 - Article
AN - SCOPUS:84909986900
SN - 0011-393X
VL - 76
SP - 110
EP - 115
JO - Current Therapeutic Research - Clinical and Experimental
JF - Current Therapeutic Research - Clinical and Experimental
ER -