TY - JOUR
T1 - Ultrasonographic guideline for thyroid nodules cytology
T2 - Single institute experience
AU - Kim, Kwang Min
AU - Park, Joon Beom
AU - Kang, Seong Joon
AU - Bae, Keum Seok
PY - 2013/2
Y1 - 2013/2
N2 - Purpose: The main issue with the current ultrasonography (US) guidelines is the overestimation of malignant and indeterminate nodules as they do not aid in making decisions to treat patients. To overcome this, new US guidelines for thyroid nodules that have been shown to be better correlated with cytologic results have been proposed. We also suggested specific indications for US-guided fine needle aspiration (FNA) using the new US guidelines. Methods: Clinical and pathologic data from 925 patients and 1,419 thyroid nodules were retrospectively collected. All subjects underwent US- and US-guided FNA at Department of Surgery, Wonju Christian Hospital, between March 2010 and July 2011. Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) were calculated for both the current guidelines and the new guidelines. Results: The accuracy, sensitivity, specificity, PPV, and NPV for the current guidelines in predicting malignancy were 24.1%, 99.3%, 62.2%, 25.0%, and 99.8%, respectively. The accuracy, sensitivity, specificity, PPV, and NPV for the new guidelines in predicting malignancy were 66.0%, 96.0%, 86.7%, 47.7%, and 99.4%, respectively. Conclusion: The use of the new US guidelines allow for a more accurate and specific diagnosis and a better treatment plan than the current guidelines. Additionally, the use of the new FNA guidelines may help prevent unnecessary FNAs and promote cost-effective follow-up for patients.
AB - Purpose: The main issue with the current ultrasonography (US) guidelines is the overestimation of malignant and indeterminate nodules as they do not aid in making decisions to treat patients. To overcome this, new US guidelines for thyroid nodules that have been shown to be better correlated with cytologic results have been proposed. We also suggested specific indications for US-guided fine needle aspiration (FNA) using the new US guidelines. Methods: Clinical and pathologic data from 925 patients and 1,419 thyroid nodules were retrospectively collected. All subjects underwent US- and US-guided FNA at Department of Surgery, Wonju Christian Hospital, between March 2010 and July 2011. Sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) were calculated for both the current guidelines and the new guidelines. Results: The accuracy, sensitivity, specificity, PPV, and NPV for the current guidelines in predicting malignancy were 24.1%, 99.3%, 62.2%, 25.0%, and 99.8%, respectively. The accuracy, sensitivity, specificity, PPV, and NPV for the new guidelines in predicting malignancy were 66.0%, 96.0%, 86.7%, 47.7%, and 99.4%, respectively. Conclusion: The use of the new US guidelines allow for a more accurate and specific diagnosis and a better treatment plan than the current guidelines. Additionally, the use of the new FNA guidelines may help prevent unnecessary FNAs and promote cost-effective follow-up for patients.
UR - http://www.scopus.com/inward/record.url?scp=84874778892&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84874778892&partnerID=8YFLogxK
U2 - 10.4174/jkss.2013.84.2.73
DO - 10.4174/jkss.2013.84.2.73
M3 - Article
C2 - 23396617
AN - SCOPUS:84874778892
SN - 1226-0053
VL - 84
SP - 73
EP - 79
JO - Journal of the Korean Surgical Society
JF - Journal of the Korean Surgical Society
IS - 2
ER -