The ratio of measured and reference effective orifice areas for discriminating prosthetic aortic valve obstruction

Kyu Kim, Dae Young Kim, Jiwon Seo, Iksung Cho, Chi Young Shim, Geu Ru Hong, Jong Won Ha

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

Aims We aimed to evaluate the efficacy of the measured effective orifice area (EOA)/reference EOA ratio in discriminating mechanical prosthetic aortic valve (PAV) obstruction. Methods This is a retrospective study of 193 mechanical PAV patients with an elevated mean transprosthetic pressure gradient (PG) and results over 20 mmHg or peak velocity over 3 m/s. Of those, 143 patients were objectively proven PAV obstruction with cardiac computed tomography or surgical inspection. The EOA was measured using the continuity equation, and the reference EOA values were obtained from previous guidelines. The measured/reference EOA ratio was significantly lower in the obstruction group (0.63 ± 0.18 vs. 0.86 ± 0.17; P < 0.001). The EOA ratio added incremental value for discriminating obstruction from the conventional parameters recommended in the guidelines. Receiver operating characteristic curve analysis revealed that the measured/reference EOA ratio discriminated PAV obstruction from those without obstruction [area under the curve (AUC), 0.840; 95% confidence interval, 0.783–0.898; P < 0.001]. A cutoff of 0.71 had 73.4% sensitivity and 82.0% specificity. The novel diagnostic algorithm adding the EOA ratio had similar accuracy to previous guideline algorithms, including reference EOA, and conventional Doppler parameters (AUC, 0.763 vs. 0.731; P = 0.309). In patients with a large PAV (≥23 mm), the novel algorithm had higher accuracy than the previous algorithm (AUC, 0.788 vs. 0.642; P = 0.019). Conclusion The ratio of measured/reference EOA adds incremental value over conventional Doppler parameters and might be helpful for distinguishing PAV obstruction.

Original languageEnglish
Pages (from-to)232-240
Number of pages9
JournalEuropean heart journal cardiovascular Imaging
Volume24
Issue number2
DOIs
Publication statusPublished - 2023 Feb 1

Bibliographical note

Publisher Copyright:
© The Author(s) 2022. Published by Oxford University Press on behalf of the European Society of Cardiology. All rights reserved.

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'The ratio of measured and reference effective orifice areas for discriminating prosthetic aortic valve obstruction'. Together they form a unique fingerprint.

Cite this