TY - JOUR
T1 - The ratio of glycated albumin to glycated haemoglobin correlates with insulin secretory function
AU - Kim, Daham
AU - Kim, Kwang J.
AU - Huh, Ji H.
AU - Lee, Byung Wan
AU - Kang, Eun S.
AU - Cha, Bong S.
AU - Lee, Hyun C.
PY - 2012/11
Y1 - 2012/11
N2 - Objective Although glycated haemoglobin (A1c) levels are similar among patients with type 2 diabetes, the glycated albumin (GA)/A1c ratio varies considerably. On the basis of the hypothesis that endogenous insulin secretion might be correlated with the GA/A1c ratio, we investigated whether insulin secretory function or insulin resistance has different effects on the GA/A1c ratio in patients with type 2 diabetes using the standardized liquid meal test. Design A clinical, retrospective study. Patients and measurements A total of 758 patients with type 2 diabetes ingested a standardized liquid meal (i.e. 500 kcal, 17·5 g fat, 68·5 g carbohydrate and 17·5 g protein). The subjects were divided into two groups: those with GA/A1c ratio <2·5 (n = 414) and those with GA/A1c ratio ≥2·5 (n = 344). We compared the A1c and GA levels, and the GA/A1c ratio and evaluated the relationships between the glycaemic indices and other parameters. Effects of β-cell function [homeostasis model assessment (HOMA-β), insulinogenic index (IGI)] and insulin resistance (HOMA-IR) on the GA/A1c ratio were also examined. Results The GA/A1c ratio was significantly correlated with HOMA-β, IGI and body mass index (BMI) but not with HOMA-IR. Furthermore, after adjusting for age, gender, BMI, haemoglobin and albumin levels, the GA/A1c ratio was still inversely correlated with both HOMA-β and IGI. Conclusions The GA/A1c ratio is significantly correlated with insulin secretory function but not with insulin resistance.
AB - Objective Although glycated haemoglobin (A1c) levels are similar among patients with type 2 diabetes, the glycated albumin (GA)/A1c ratio varies considerably. On the basis of the hypothesis that endogenous insulin secretion might be correlated with the GA/A1c ratio, we investigated whether insulin secretory function or insulin resistance has different effects on the GA/A1c ratio in patients with type 2 diabetes using the standardized liquid meal test. Design A clinical, retrospective study. Patients and measurements A total of 758 patients with type 2 diabetes ingested a standardized liquid meal (i.e. 500 kcal, 17·5 g fat, 68·5 g carbohydrate and 17·5 g protein). The subjects were divided into two groups: those with GA/A1c ratio <2·5 (n = 414) and those with GA/A1c ratio ≥2·5 (n = 344). We compared the A1c and GA levels, and the GA/A1c ratio and evaluated the relationships between the glycaemic indices and other parameters. Effects of β-cell function [homeostasis model assessment (HOMA-β), insulinogenic index (IGI)] and insulin resistance (HOMA-IR) on the GA/A1c ratio were also examined. Results The GA/A1c ratio was significantly correlated with HOMA-β, IGI and body mass index (BMI) but not with HOMA-IR. Furthermore, after adjusting for age, gender, BMI, haemoglobin and albumin levels, the GA/A1c ratio was still inversely correlated with both HOMA-β and IGI. Conclusions The GA/A1c ratio is significantly correlated with insulin secretory function but not with insulin resistance.
UR - http://www.scopus.com/inward/record.url?scp=84867263826&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84867263826&partnerID=8YFLogxK
U2 - 10.1111/j.1365-2265.2011.04312.x
DO - 10.1111/j.1365-2265.2011.04312.x
M3 - Article
C2 - 22150917
AN - SCOPUS:84867263826
SN - 0300-0664
VL - 77
SP - 679
EP - 683
JO - Clinical Endocrinology
JF - Clinical Endocrinology
IS - 5
ER -