TY - JOUR
T1 - The feasibility of solo-surgeon living donor nephrectomy
T2 - Initial experience using video-assisted minilaparotomy surgery
AU - Lee, Yong Seung
AU - Jeon, Hwang Gyun
AU - Lee, Seung Ryeol
AU - Jeong, Woo Ju
AU - Yang, Seung Choul
AU - Han, Woong Kyu
PY - 2010/11
Y1 - 2010/11
N2 - Background: Today, many kinds of surgery are being conducted without human assistants. Living donor nephrectomy (LDN) using video-assisted minilaparotomy surgery (VAM) has been performed by solo-surgeon using Unitrac® (Aesculap Surgical Instrument, Germany). We examined the results from VAM-solo-surgeon living donor nephrectomy (SLDN) and conventional VAM-human-assisted living donor nephrectomy (HLDN). Methods: Between July 2007 and April 2008, 82 cases of VAM-LDN were performed by two surgeons. From these cases, we randomly assigned 35 cases to undergo solo-surgery (group I) and the other 47 cases to undergo surgery with one human assistant (group II). All VAM-LDN procedures were performed in the same manner. Only the roles of a first assistant were substituted by the Unitrac® in group I. We compared the perioperative and postoperative data, including operative time, estimated blood loss, and hospital stay, between the two groups. We also investigated cases that developed complications. Results: There were no significant differences in the patient demographic data between the two groups (P > 0.05). The mean operative time was 201.9 ± 32.9 min in group I and 202.4 ± 48.3 min in group II (P = 0.954), whereas mean blood loss was 209.7 ± 167.3 ml in group I and 179.6 ± 87.8 ml in group II (P = 0.294). Postoperative hospital stay were 5.4 ± 1.1 days in group I and 5.5 ± 1.6 days in group II (P = 0.813). The incidence of perioperative complications was not significantly different between the two groups. Conclusions: Our study demonstrates that VAM-SLDN can be performed safely, is economically beneficial, and is comparable to VAM-HLDN in terms of postoperative outcomes.
AB - Background: Today, many kinds of surgery are being conducted without human assistants. Living donor nephrectomy (LDN) using video-assisted minilaparotomy surgery (VAM) has been performed by solo-surgeon using Unitrac® (Aesculap Surgical Instrument, Germany). We examined the results from VAM-solo-surgeon living donor nephrectomy (SLDN) and conventional VAM-human-assisted living donor nephrectomy (HLDN). Methods: Between July 2007 and April 2008, 82 cases of VAM-LDN were performed by two surgeons. From these cases, we randomly assigned 35 cases to undergo solo-surgery (group I) and the other 47 cases to undergo surgery with one human assistant (group II). All VAM-LDN procedures were performed in the same manner. Only the roles of a first assistant were substituted by the Unitrac® in group I. We compared the perioperative and postoperative data, including operative time, estimated blood loss, and hospital stay, between the two groups. We also investigated cases that developed complications. Results: There were no significant differences in the patient demographic data between the two groups (P > 0.05). The mean operative time was 201.9 ± 32.9 min in group I and 202.4 ± 48.3 min in group II (P = 0.954), whereas mean blood loss was 209.7 ± 167.3 ml in group I and 179.6 ± 87.8 ml in group II (P = 0.294). Postoperative hospital stay were 5.4 ± 1.1 days in group I and 5.5 ± 1.6 days in group II (P = 0.813). The incidence of perioperative complications was not significantly different between the two groups. Conclusions: Our study demonstrates that VAM-SLDN can be performed safely, is economically beneficial, and is comparable to VAM-HLDN in terms of postoperative outcomes.
UR - http://www.scopus.com/inward/record.url?scp=78650187070&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=78650187070&partnerID=8YFLogxK
U2 - 10.1007/s00464-010-1040-z
DO - 10.1007/s00464-010-1040-z
M3 - Article
C2 - 20383533
AN - SCOPUS:78650187070
SN - 0930-2794
VL - 24
SP - 2755
EP - 2759
JO - Surgical endoscopy
JF - Surgical endoscopy
IS - 11
ER -