TY - JOUR
T1 - Stress distributions in peri-miniscrew areas from cylindrical and tapered miniscrews inserted at different angles
AU - Choia, Sung Hwan
AU - Kim, Seong Jin
AU - Leea, Kee Joon
AU - Sung, Sang Jin
AU - Chun, Youn Sic
AU - Hwang, Chung Ju
N1 - Publisher Copyright:
© 2015 The Korean Association of Orthodontists.
PY - 2016/7
Y1 - 2016/7
N2 - Objective: The purpose of this study was to analyze stress distributions in the roots, periodontal ligaments (PDLs), and bones around cylindrical and tapered miniscrews inserted at different angles using a finite element analysis. Methods: We created a three-dimensional (3D) maxilla model of a dentition with extracted first premolars and used 2 types of miniscrews (tapered and cylindrical) with 1.45-mm diameters and 8-mm lengths. The miniscrews were inserted at 30o, 60o, and 90o angles with respect to the bone surface. A simulated horizontal orthodontic force of 2 N was applied to the miniscrew heads. Then, the stress distributions, magnitudes during miniscrew placement, and force applications were analyzed with a 3D finite element analysis. Results: Stresses were primarily absorbed by cortical bone. Moreover, very little stress was transmitted to the roots, PDLs, and cancellous bone. During cylindrical miniscrew insertion, the maximum von Mises stress increased as insertion angle decreased. Tapered miniscrews exhibited greater maximum von Mises stress than cylindrical miniscrews. During force application, maximum von Mises stresses increased in both groups as insertion angles decreased. Conclusions: For both cylindrical and tapered miniscrew designs, placement as perpendicular to the bone surface as possible is recommended to reduce stress in the surrounding bone.
AB - Objective: The purpose of this study was to analyze stress distributions in the roots, periodontal ligaments (PDLs), and bones around cylindrical and tapered miniscrews inserted at different angles using a finite element analysis. Methods: We created a three-dimensional (3D) maxilla model of a dentition with extracted first premolars and used 2 types of miniscrews (tapered and cylindrical) with 1.45-mm diameters and 8-mm lengths. The miniscrews were inserted at 30o, 60o, and 90o angles with respect to the bone surface. A simulated horizontal orthodontic force of 2 N was applied to the miniscrew heads. Then, the stress distributions, magnitudes during miniscrew placement, and force applications were analyzed with a 3D finite element analysis. Results: Stresses were primarily absorbed by cortical bone. Moreover, very little stress was transmitted to the roots, PDLs, and cancellous bone. During cylindrical miniscrew insertion, the maximum von Mises stress increased as insertion angle decreased. Tapered miniscrews exhibited greater maximum von Mises stress than cylindrical miniscrews. During force application, maximum von Mises stresses increased in both groups as insertion angles decreased. Conclusions: For both cylindrical and tapered miniscrew designs, placement as perpendicular to the bone surface as possible is recommended to reduce stress in the surrounding bone.
UR - http://www.scopus.com/inward/record.url?scp=84979500182&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84979500182&partnerID=8YFLogxK
U2 - 10.4041/kjod.2016.46.4.189
DO - 10.4041/kjod.2016.46.4.189
M3 - Article
AN - SCOPUS:84979500182
SN - 2234-7518
VL - 46
SP - 189
EP - 198
JO - Korean Journal of Orthodontics
JF - Korean Journal of Orthodontics
IS - 4
ER -