TY - JOUR
T1 - Standardized multi-institutional data analysis of fixed and removable prosthesis
T2 - estimation of life expectancy with regards to variable risk factors
AU - Jeon, Hae In
AU - Yoon, Joon Ho
AU - Kim, Jeong Hoon
AU - Kim, Dong Wook
AU - Oh, Namsik
AU - Park, Young Bum
N1 - Publisher Copyright:
© (2024), (Korean Academy of Prosthodontic). All Rights Reserved.
PY - 2024
Y1 - 2024
N2 - PURPOSE. This study aims to assess and predict lifespan of dental prostheses using newly developed Korean Association of Prosthodontics (KAP) criteria through a large-scale, multi-institutional survey. MATERIALS AND METHODS. Survey was conducted including 16 institutions. Cox proportional hazards model and principal component analysis (PCA) were used to find out relevant factors and predict life expectancy. RESULTS. 1,703 fixed and 815 removable prostheses data were collected and evaluated. Statistically significant factors in fixed prosthesis failure were plaque index and material type, with a median survival of 10 to 18 years and 14 to 20 years each. In removable prosthesis, factors were national health insurance coverage, antagonist type, and prosthesis type (complete or partial denture), with median survival of 10 to 13 years, 11 to 14 years, and 10 to 15 years each. For still-usable prostheses, PCA analysis predicted an additional 3 years in fixed and 4.8 years in removable prosthesis. CONCLUSION. Life expectancy of a prosthesis differed significantly by factors mostly controllable either by dentist or a patient. Overall life expectancy was shown to be longer than previous research.
AB - PURPOSE. This study aims to assess and predict lifespan of dental prostheses using newly developed Korean Association of Prosthodontics (KAP) criteria through a large-scale, multi-institutional survey. MATERIALS AND METHODS. Survey was conducted including 16 institutions. Cox proportional hazards model and principal component analysis (PCA) were used to find out relevant factors and predict life expectancy. RESULTS. 1,703 fixed and 815 removable prostheses data were collected and evaluated. Statistically significant factors in fixed prosthesis failure were plaque index and material type, with a median survival of 10 to 18 years and 14 to 20 years each. In removable prosthesis, factors were national health insurance coverage, antagonist type, and prosthesis type (complete or partial denture), with median survival of 10 to 13 years, 11 to 14 years, and 10 to 15 years each. For still-usable prostheses, PCA analysis predicted an additional 3 years in fixed and 4.8 years in removable prosthesis. CONCLUSION. Life expectancy of a prosthesis differed significantly by factors mostly controllable either by dentist or a patient. Overall life expectancy was shown to be longer than previous research.
KW - Fixed prosthesis
KW - Life expectancy
KW - Multi-institutional data analysis
KW - Principal component analysis
KW - Removable prosthesis
UR - http://www.scopus.com/inward/record.url?scp=85193704063&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85193704063&partnerID=8YFLogxK
U2 - 10.4047/jap.2024.16.2.67
DO - 10.4047/jap.2024.16.2.67
M3 - Article
AN - SCOPUS:85193704063
SN - 2005-7806
VL - 16
SP - 67
EP - 76
JO - Journal of Advanced Prosthodontics
JF - Journal of Advanced Prosthodontics
IS - 2
ER -