Simulation of miniscrew-root distance available for molar distalization depending on the miniscrew insertion angle and vertical facial type

Ju Hyun Yoon, Jung Yul Cha, Yoon Jeong Choi, Won Se Park, Sang Sun Han, Kee Joon Lee

Research output: Contribution to journalArticlepeer-review

6 Citations (Scopus)

Abstract

Objective The purpose of this study was to evaluate the effects of miniscrew insertion angle and vertical facial type on the interradicular miniscrew-root distance available for molar distalization. Materials and methods Cone-beam computed tomography images of 60 adults with skeletal Class I occlusion exhibiting hyperdivergent (n = 20), normodivergent (n = 20), and hypodivergent (n = 20) facial types were used. Placement of a 6-mm long, 1.5-mm diameter, tapered miniscrew was simulated at a site 4 mm apical to the cementoenamel junction, with insertion angles of 0°, 30°, 45°, and 60° relative to the transverse occlusal plane. The shortest linear distance between the miniscrew and anterior root at four interradicular sites was measured: Maxillary second premolar and first molar (Mx 5-6), maxillary first and second molars (Mx 6-7), mandibular second premolar and first molar (Mn 5-6), and mandibular first and second molars (Mn 6-7). Results Miniscrew-root distance significantly increased as the insertion angle increased from 0° to 60°. In the mandible, the distances significantly differed among vertical facial types, increasing in the following order: Hyperdivergent, normodivergent, and hypodivergent. The minimum mean distance was found in the Mx 6-7 (30°; 0.86±0.35 mm), and the maximum mean distance was found in the Mn 5-6 (60°; 2.64±0.56 mm). The rates of miniscrews located buccally outside the root distalization path were up to 70% and 55% when the miniscrews were placed at 60° insertion angles in the Mx 5-6 and Mn 5-6 regions, respectively. Conclusions Miniscrew-root distance increased significantly with the increased insertion angle, and the amount of increase was affected by the miniscrew placement site and vertical facial type. To ensure adequate distalization of the posterior segment, the miniscrew should be inserted at an angle in the interradicular area between the second premolar and first molar.

Original languageEnglish
Article numbere0239759
JournalPloS one
Volume15
Issue number9 September
DOIs
Publication statusPublished - 2020 Sept

Bibliographical note

Publisher Copyright:
© 2020 Yoon et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

All Science Journal Classification (ASJC) codes

  • General

Fingerprint

Dive into the research topics of 'Simulation of miniscrew-root distance available for molar distalization depending on the miniscrew insertion angle and vertical facial type'. Together they form a unique fingerprint.

Cite this