T1 - Semi-Quantitative Strain Ratio Determined Using Different Measurement Methods
T2 - Comparison of Strain Ratio Values and Diagnostic Performance Using One- versus Two-Region-of-Interest Measurement
AU - Yoon, Jung Hyun
AU - Song, Mi Kyung
AU - Kim, Eun Kyung
N1 - Publisher Copyright:
© 2017
PY - 2017/5/1
Y1 - 2017/5/1
N2 - We evaluated the agreement and diagnostic performance of strain ratio values using measurements made with one and two user-defined regions of interest (ROIs) on breast elastography. Two hundred forty-three breast masses of 226 women (mean age: 48.2 y) were included. Ultrasonography (US) and elastography images of the masses were recorded. Strain ratio was measured twice on the same elastography image; strain ratio 1, applying one ROI at the target mass for measurement, and strain ratio 2, applying one ROI at the target mass and another ROI as reference strain. The two strain ratio measurements were in substantial agreement, with an intra-class correlation coefficient of 0.655 (95% confidence interval: 0.577–0.722). Specificity, positive predictive value and accuracy (cutoffs: 2.66 and 2.35) were significantly improved for US combined with the two strain ratio measurements (all p values < 0.05). Strain ratios measured using one or two user-defined ROIs were in substantial agreement, both contributing to the improved diagnostic performance of breast US.
AB - We evaluated the agreement and diagnostic performance of strain ratio values using measurements made with one and two user-defined regions of interest (ROIs) on breast elastography. Two hundred forty-three breast masses of 226 women (mean age: 48.2 y) were included. Ultrasonography (US) and elastography images of the masses were recorded. Strain ratio was measured twice on the same elastography image; strain ratio 1, applying one ROI at the target mass for measurement, and strain ratio 2, applying one ROI at the target mass and another ROI as reference strain. The two strain ratio measurements were in substantial agreement, with an intra-class correlation coefficient of 0.655 (95% confidence interval: 0.577–0.722). Specificity, positive predictive value and accuracy (cutoffs: 2.66 and 2.35) were significantly improved for US combined with the two strain ratio measurements (all p values < 0.05). Strain ratios measured using one or two user-defined ROIs were in substantial agreement, both contributing to the improved diagnostic performance of breast US.
UR - http://www.scopus.com/inward/record.url?scp=85013794503&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85013794503&partnerID=8YFLogxK
U2 - 10.1016/j.ultrasmedbio.2017.01.005
DO - 10.1016/j.ultrasmedbio.2017.01.005
M3 - Article
C2 - 28242085
AN - SCOPUS:85013794503
SN - 0301-5629
VL - 43
SP - 911
EP - 917
JO - Ultrasound in Medicine and Biology
JF - Ultrasound in Medicine and Biology
IS - 5
ER -