TY - JOUR
T1 - Safety of capsule endoscopy using human body communication in patients with cardiac devices
AU - Chung, Joo Won
AU - Hwang, Hye Jin
AU - Chung, Moon Jae
AU - Park, Jeong Youp
AU - Pak, Hui Nam
AU - Song, Si Young
PY - 2012/6
Y1 - 2012/6
N2 - Background: The MiroCam (IntroMedic, Ltd., Seoul, Korea) is a small-bowel capsule endoscope that uses human body communication to transmit data. The potential interactions between cardiac devices and the capsule endoscope are causes for concern, but no data are available for this matter. Aim: This clinical study was designed to evaluate the potential influence of the MiroCam capsules on cardiac devices. Methods: Patients with cardiac pacemakers or implantable cardiac defibrillators referred for evaluation of small bowel disease were prospectively enrolled in this study. Before capsule endoscopy, a cardiologist checked baseline electrocardiograms and functions of the cardiac devices. Cardiac rhythms were continuously monitored by 24-h telemetry during capsule endoscopy in the hospital. After completion of procedures, functions of the cardiac devices were checked again for interference. Images from the capsule endoscopy were reviewed and analyzed for technical problems. Results: Six patients, three with pacemakers and three with implantable cardiac defibrillators, were included in the study. We identified no disturbances in the cardiac devices and no arrhythmias detected on telemetry monitoring during capsule endoscopy. No significant changes in the programmed parameters of the cardiac devices were noted after capsule endoscopy. There were no imaging disturbances from the cardiac devices on capsule endoscopy. Conclusions: Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.
AB - Background: The MiroCam (IntroMedic, Ltd., Seoul, Korea) is a small-bowel capsule endoscope that uses human body communication to transmit data. The potential interactions between cardiac devices and the capsule endoscope are causes for concern, but no data are available for this matter. Aim: This clinical study was designed to evaluate the potential influence of the MiroCam capsules on cardiac devices. Methods: Patients with cardiac pacemakers or implantable cardiac defibrillators referred for evaluation of small bowel disease were prospectively enrolled in this study. Before capsule endoscopy, a cardiologist checked baseline electrocardiograms and functions of the cardiac devices. Cardiac rhythms were continuously monitored by 24-h telemetry during capsule endoscopy in the hospital. After completion of procedures, functions of the cardiac devices were checked again for interference. Images from the capsule endoscopy were reviewed and analyzed for technical problems. Results: Six patients, three with pacemakers and three with implantable cardiac defibrillators, were included in the study. We identified no disturbances in the cardiac devices and no arrhythmias detected on telemetry monitoring during capsule endoscopy. No significant changes in the programmed parameters of the cardiac devices were noted after capsule endoscopy. There were no imaging disturbances from the cardiac devices on capsule endoscopy. Conclusions: Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.
UR - http://www.scopus.com/inward/record.url?scp=84864278677&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84864278677&partnerID=8YFLogxK
U2 - 10.1007/s10620-012-2067-x
DO - 10.1007/s10620-012-2067-x
M3 - Article
C2 - 22311369
AN - SCOPUS:84864278677
SN - 0163-2116
VL - 57
SP - 1719
EP - 1723
JO - Digestive diseases and sciences
JF - Digestive diseases and sciences
IS - 6
ER -