N2 - While the preservation of historic buildings is important, they must remain usable. The comfort of occupants using the historic building must be considered due to the change of use. In this study, a 100-year-old building in Korea, protected as a cultural heritage site, is retrofitted. Buildings currently in continuous use as cafes require improvement of low building performance due to aging materials. The energy performance and sound environment of the target building were improved by recycling café generated coffee waste. Recycled coffee waste uses a phase change material, increasing its latent heat. DesignBuilder simulation, a building energy performance analysis software, analyzed energy consumption and room temperature before and after retrofit. C10 containing 10% of the phase change material of coffee waste board showed high efficiency, saving heating energy after retrofit. After retrofit according to the material sound absorption coefficient, ODEON simulation confirmed improvement of the indoor sound environment. The measured sound pressure level was 73.95 and 75.15 dB in the 500 and 1,000 Hz frequency bands, respectively; however, after implementing improvements, the sound pressure level decreased by up to 7.39%. Reverberation time was observed as high as 1.47 s and 1.83 s for the 500 and 1000 Hz frequency bands, respectively, and decreased by up to 66.67%. Therefore, application of coffee waste board to the retrofit of historic buildings is effective in improving indoor environment.
AB - While the preservation of historic buildings is important, they must remain usable. The comfort of occupants using the historic building must be considered due to the change of use. In this study, a 100-year-old building in Korea, protected as a cultural heritage site, is retrofitted. Buildings currently in continuous use as cafes require improvement of low building performance due to aging materials. The energy performance and sound environment of the target building were improved by recycling café generated coffee waste. Recycled coffee waste uses a phase change material, increasing its latent heat. DesignBuilder simulation, a building energy performance analysis software, analyzed energy consumption and room temperature before and after retrofit. C10 containing 10% of the phase change material of coffee waste board showed high efficiency, saving heating energy after retrofit. After retrofit according to the material sound absorption coefficient, ODEON simulation confirmed improvement of the indoor sound environment. The measured sound pressure level was 73.95 and 75.15 dB in the 500 and 1,000 Hz frequency bands, respectively; however, after implementing improvements, the sound pressure level decreased by up to 7.39%. Reverberation time was observed as high as 1.47 s and 1.83 s for the 500 and 1000 Hz frequency bands, respectively, and decreased by up to 66.67%. Therefore, application of coffee waste board to the retrofit of historic buildings is effective in improving indoor environment.
KW - Building energy performance
KW - Cultural heritage conservation
KW - Energy retrofit
KW - Historic building
KW - Indoor environment
KW - Reverberation time
UR - http://www.scopus.com/inward/record.url?scp=85150277458&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85150277458&partnerID=8YFLogxK
U2 - 10.1016/j.enbuild.2023.112988
DO - 10.1016/j.enbuild.2023.112988
M3 - Article
AN - SCOPUS:85150277458
SN - 0378-7788
VL - 287
JO - Energy and Buildings
JF - Energy and Buildings
M1 - 112988
ER -