T1 - Performance of Transient Elastography for the Staging of Liver Fibrosis in Patients with Chronic Hepatitis B
T2 - A Meta-Analysis
AU - Chon, Young Eun
AU - Choi, Eun Hee
AU - Song, Ki Jun
AU - Park, Jun Yong
AU - Kim, Do Young
AU - Han, Kwang Hyub
AU - Chon, Chae Yoon
AU - Ahn, Sang Hoon
AU - Kim, Seung Up
PY - 2012/9/25
Y1 - 2012/9/25
N2 - Background: Transient elastography (TE), a non-invasive tool that measures liver stiffness, has been evaluated in meta-analyses for effectiveness in assessing liver fibrosis in European populations with chronic hepatitis C (CHC). However, these data cannot be extrapolated to populations in Asian countries, where chronic hepatitis B (CHB) is more prevalent. In this study, we performed a meta-analysis to assess the overall performance of TE for assessing liver fibrosis in patients with CHB. Methods: Studies from the literature and international conference abstracts which enrolled only patients with CHB or performed a subgroup analysis of such patients were enrolled. Combined effects were calculated using area under the receiver operating characteristic curves (AUROC) and diagnostic accuracy values of each study. Result: A total of 18 studies comprising 2,772 patients were analyzed. The mean AUROCs for the diagnosis of significant fibrosis (F2), severe fibrosis (F3), and cirrhosis (F4) were 0.859 (95% confidence interval [CI], 0.857-0.860), 0.887 (95% CI, 0.886-0.887), and 0.929 (95% CI, 0.928-0.929), respectively. The estimated cutoff for F2 was 7.9 (range, 6.1-11.8) kPa, with a sensitivity of 74.3% and specificity of 78.3%. For F3, the cutoff value was determined to be 8.8 (range, 8.1-9.7) kPa, with a sensitivity of 74.0% and specificity of 63.8%. The cutoff value for F4 was 11.7 (range, 7.3-17.5) kPa, with a sensitivity of 84.6% and specificity of 81.5%. Conclusion: TE can be performed with good diagnostic accuracy for quantifying liver fibrosis in patients with CHB.
AB - Background: Transient elastography (TE), a non-invasive tool that measures liver stiffness, has been evaluated in meta-analyses for effectiveness in assessing liver fibrosis in European populations with chronic hepatitis C (CHC). However, these data cannot be extrapolated to populations in Asian countries, where chronic hepatitis B (CHB) is more prevalent. In this study, we performed a meta-analysis to assess the overall performance of TE for assessing liver fibrosis in patients with CHB. Methods: Studies from the literature and international conference abstracts which enrolled only patients with CHB or performed a subgroup analysis of such patients were enrolled. Combined effects were calculated using area under the receiver operating characteristic curves (AUROC) and diagnostic accuracy values of each study. Result: A total of 18 studies comprising 2,772 patients were analyzed. The mean AUROCs for the diagnosis of significant fibrosis (F2), severe fibrosis (F3), and cirrhosis (F4) were 0.859 (95% confidence interval [CI], 0.857-0.860), 0.887 (95% CI, 0.886-0.887), and 0.929 (95% CI, 0.928-0.929), respectively. The estimated cutoff for F2 was 7.9 (range, 6.1-11.8) kPa, with a sensitivity of 74.3% and specificity of 78.3%. For F3, the cutoff value was determined to be 8.8 (range, 8.1-9.7) kPa, with a sensitivity of 74.0% and specificity of 63.8%. The cutoff value for F4 was 11.7 (range, 7.3-17.5) kPa, with a sensitivity of 84.6% and specificity of 81.5%. Conclusion: TE can be performed with good diagnostic accuracy for quantifying liver fibrosis in patients with CHB.
UR - http://www.scopus.com/inward/record.url?scp=84866658173&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84866658173&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0044930
DO - 10.1371/journal.pone.0044930
M3 - Article
C2 - 23049764
AN - SCOPUS:84866658173
SN - 1932-6203
VL - 7
JO - PloS one
JF - PloS one
IS - 9
M1 - e44930
ER -