TY - JOUR
T1 - Noninvasive and Continuous Monitoring of the Core Body Temperature through the Quantitative Measurement of Blood Perfusion Rate
AU - Park, Gimin
AU - Woo, Seungjai
AU - Kim, Kyomin
AU - Kim, Jiyong
AU - Hwang, Junphil
AU - Kim, Sang Kyu
AU - Lee, Hotaik
AU - Lee, Soyoung
AU - Kwon, Boksoon
AU - Kim, Sungho
AU - Rhee, Hongsoon
AU - Kim, Woochul
N1 - Publisher Copyright:
© 2023 American Chemical Society.
PY - 2023/8/25
Y1 - 2023/8/25
N2 - Core body temperature (CBT) is one of the four vital signs that must be monitored continuously. The continuous recording of CBT is possible through invasive methods by inserting a temperature probe into specific body sites. We report a novel method to monitor CBT through the quantitative measurement of skin blood perfusion rate (ωb,skin). By monitoring the skin temperature, heat flux, and ωb,skin, the arterial blood temperature, equivalent to CBT, can be extracted. ωb,skin is quantitatively evaluated thermally via sinusoidal heating with regulated thermal penetration depth so that the blood perfusion rate is acquired only in the skin. Its quantification is significant because it indicates various physiological events including hyper- or hypothermia, tissue death, and delineation of tumors. A subject showed promising results with steady values of ωb,skin and CBT of 5.2 ± 1.05 × 10-4 s-1 and 36.51 ± 0.23 °C, respectively. For periods where the subject’s actual CBT (axillary temperature) did not fall within the estimated range, the average deviation from the actual CBT was only 0.07 °C. This study aims to develop a competent methodology capable of continuously monitoring the CBT and blood perfusion rate at a distant location from the core body region for the diagnosis of a patient’s health condition with wearable devices.
AB - Core body temperature (CBT) is one of the four vital signs that must be monitored continuously. The continuous recording of CBT is possible through invasive methods by inserting a temperature probe into specific body sites. We report a novel method to monitor CBT through the quantitative measurement of skin blood perfusion rate (ωb,skin). By monitoring the skin temperature, heat flux, and ωb,skin, the arterial blood temperature, equivalent to CBT, can be extracted. ωb,skin is quantitatively evaluated thermally via sinusoidal heating with regulated thermal penetration depth so that the blood perfusion rate is acquired only in the skin. Its quantification is significant because it indicates various physiological events including hyper- or hypothermia, tissue death, and delineation of tumors. A subject showed promising results with steady values of ωb,skin and CBT of 5.2 ± 1.05 × 10-4 s-1 and 36.51 ± 0.23 °C, respectively. For periods where the subject’s actual CBT (axillary temperature) did not fall within the estimated range, the average deviation from the actual CBT was only 0.07 °C. This study aims to develop a competent methodology capable of continuously monitoring the CBT and blood perfusion rate at a distant location from the core body region for the diagnosis of a patient’s health condition with wearable devices.
KW - Core body temperature
KW - bioheat transfer
KW - blood perfusion rate
KW - continuous monitoring
UR - http://www.scopus.com/inward/record.url?scp=85165901685&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85165901685&partnerID=8YFLogxK
U2 - 10.1021/acssensors.3c00273
DO - 10.1021/acssensors.3c00273
M3 - Article
C2 - 37432871
AN - SCOPUS:85165901685
SN - 2379-3694
VL - 8
SP - 2975
EP - 2985
JO - ACS Sensors
JF - ACS Sensors
IS - 8
ER -