TY - GEN
T1 - New retrofitting method for rectangular high strength RC columns by CFS jacketing after octagonal cross section shape conversion
AU - Kim, Jang Ho Jay
AU - Kim, Tae Kyun
AU - Choi, Jin Won
AU - Choi, Seung Jai
AU - Shin, Dong Woo
AU - Shin, Jae Ho
PY - 2014
Y1 - 2014
N2 - Numerous studies showed that safety and serviceability of many concrete infrastructures and buildings built in 1970's have far less strength capacities than their design capacities and thereby require immediate retrofitting. Currently, these aged concrete structures are being repaired using many repair and strengthening methods developed in the past. Unfortunately, the previously developed repair and strengthening methods did not fully utilize the structural member's unique mechanical characteristics. Therefore, the researches on repair and strengthening methods developed based on composite mechanical behavior between repairing material and original substrate, which can effectively improve strength, ductility, and failure mechanism are needed at this time. In addition, these repairing and strengthening method must focus on structural member constructed using high performance concrete to meet the demand of present construction trend of building mammoth structures. Therefore, in this study, a repairing and strengthening method for retrofitting high strength concrete (HSC) columns that can effectively improve the performance of HSC columns is developed. The square HSC column's crosssectional shape is converted to octagonal shape by attaching precast members on the surface of the column. Then, the octagonal column surface is jacketed using Carbon Fiber Sheets (CFS). The method allows maximum usage of confinement effect from externally jacketed CFS, which result in improved strength and ductility of repaired HSC columns. The research results are discussed in detail.
AB - Numerous studies showed that safety and serviceability of many concrete infrastructures and buildings built in 1970's have far less strength capacities than their design capacities and thereby require immediate retrofitting. Currently, these aged concrete structures are being repaired using many repair and strengthening methods developed in the past. Unfortunately, the previously developed repair and strengthening methods did not fully utilize the structural member's unique mechanical characteristics. Therefore, the researches on repair and strengthening methods developed based on composite mechanical behavior between repairing material and original substrate, which can effectively improve strength, ductility, and failure mechanism are needed at this time. In addition, these repairing and strengthening method must focus on structural member constructed using high performance concrete to meet the demand of present construction trend of building mammoth structures. Therefore, in this study, a repairing and strengthening method for retrofitting high strength concrete (HSC) columns that can effectively improve the performance of HSC columns is developed. The square HSC column's crosssectional shape is converted to octagonal shape by attaching precast members on the surface of the column. Then, the octagonal column surface is jacketed using Carbon Fiber Sheets (CFS). The method allows maximum usage of confinement effect from externally jacketed CFS, which result in improved strength and ductility of repaired HSC columns. The research results are discussed in detail.
UR - http://www.scopus.com/inward/record.url?scp=85067769626&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85067769626&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:85067769626
T3 - Proceedings of the 7th International Conference on FRP Composites in Civil Engineering, CICE 2014
BT - Proceedings of the 7th International Conference on FRP Composites in Civil Engineering, CICE 2014
A2 - El-Hacha, Raafat
PB - International Institute for FRP in Construction (IIFC)
T2 - 7th International Conference on FRP Composites in Civil Engineering, CICE 2014
Y2 - 20 August 2014 through 22 August 2014
ER -