Abstract
A practical strategy for the reduction of nanogap width has been investigated using liquid nitrogen freezing of Pd-sputtered elastomeric substrates. Two types of hydrogen gas sensors, in which no pre-strain and 25% elongation were applied to Pd films on the elastomeric substrates, showed extremely low detection limits of less than 300 and 200 ppm, respectively, after liquid nitrogen freezing and recovery to room temperature. For the non-strained sensors, the nanogap width was measured to be about 90 nm, whereas it was more reduced to 25 nm on the elongated sensors. Both sensors exhibited perfect On-Off switching, fast response, and good reversibility, which are based on the nanogap open-close mechanism upon exposure to hydrogen gas. These results provide a valuable clue for reducing nanogap width, thereby improving the hydrogen-sensing capabilities of nanogap-based On-Off hydrogen sensors.
Original language | English |
---|---|
Pages (from-to) | 140-144 |
Number of pages | 5 |
Journal | Sensors and Actuators, A: Physical |
Volume | 192 |
DOIs | |
Publication status | Published - 2013 |
Bibliographical note
Funding Information:This work was supported by the Priority Research Centers Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology ( 2009-0093823 ) and by the Converging Research Center Program through the Ministry of Education, Science, and Technology (No. 2010K001430 ).
All Science Journal Classification (ASJC) codes
- Electronic, Optical and Magnetic Materials
- Instrumentation
- Condensed Matter Physics
- Surfaces, Coatings and Films
- Metals and Alloys
- Electrical and Electronic Engineering