N2 - Miniaturized lab-on-a-chip (LOC) systems have been developed for genetic and epigenetic analyses in clinical applications because of advantages such as reduced sample size and reagent consumption, rapid processing speed, simplicity, and enhanced sensitivity. Despite tremendous efforts made towards developing LOC systems for use in the clinical setting, the development of LOC systems to analyze DNA methylation, which is an emerging epigenetic marker causing the abnormal silencing of genes including tumor suppressor genes, is still challenging because of the gold standard methods involving a bisulfite conversion step. Existing bisulfite conversion-based techniques are not suitable for clinical use due to their long processing time, labor intensiveness, and the purification steps involved. Here, we present a lab-on-a-chip system for DNA methylation analysis based on bisulfite conversion (LoMA-B), which couples a sample pre-processing module for on-chip bisulfite conversion and a label-free, real-time detection module for rapid analysis of DNA methylation status using an isothermal DNA amplification/detection technique. The methylation status of the RARβ gene in human genomic DNA extracted from MCF-7 cells was analyzed by the LoMA-B system within 80 min (except 16 h for sensor preparation) compared to conventional MS-PCR within 24 h. Furthermore, the LoMA-B system is highly sensitive and can detect as little as 1% methylated DNA in a methylated/unmethylated cell mixture. Therefore, the LoMA-B system is an efficient diagnostic tool for the simple, versatile, and quantitative evaluation of DNA methylation patterns for clinical applications.
AB - Miniaturized lab-on-a-chip (LOC) systems have been developed for genetic and epigenetic analyses in clinical applications because of advantages such as reduced sample size and reagent consumption, rapid processing speed, simplicity, and enhanced sensitivity. Despite tremendous efforts made towards developing LOC systems for use in the clinical setting, the development of LOC systems to analyze DNA methylation, which is an emerging epigenetic marker causing the abnormal silencing of genes including tumor suppressor genes, is still challenging because of the gold standard methods involving a bisulfite conversion step. Existing bisulfite conversion-based techniques are not suitable for clinical use due to their long processing time, labor intensiveness, and the purification steps involved. Here, we present a lab-on-a-chip system for DNA methylation analysis based on bisulfite conversion (LoMA-B), which couples a sample pre-processing module for on-chip bisulfite conversion and a label-free, real-time detection module for rapid analysis of DNA methylation status using an isothermal DNA amplification/detection technique. The methylation status of the RARβ gene in human genomic DNA extracted from MCF-7 cells was analyzed by the LoMA-B system within 80 min (except 16 h for sensor preparation) compared to conventional MS-PCR within 24 h. Furthermore, the LoMA-B system is highly sensitive and can detect as little as 1% methylated DNA in a methylated/unmethylated cell mixture. Therefore, the LoMA-B system is an efficient diagnostic tool for the simple, versatile, and quantitative evaluation of DNA methylation patterns for clinical applications.
UR - http://www.scopus.com/inward/record.url?scp=84939179745&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84939179745&partnerID=8YFLogxK
U2 - 10.1039/c5lc00458f
DO - 10.1039/c5lc00458f
M3 - Article
C2 - 26194344
AN - SCOPUS:84939179745
SN - 1473-0197
VL - 15
SP - 3530
EP - 3539
JO - Lab on a Chip - Miniaturisation for Chemistry and Biology
JF - Lab on a Chip - Miniaturisation for Chemistry and Biology
IS - 17
ER -