TY - JOUR
T1 - Late stent malapposition after drug-eluting stent implantation
T2 - An intravascular ultrasound analysis with long-term follow-up
AU - Hong, Myeong Ki
AU - Mintz, Gary S.
AU - Lee, Cheol Whan
AU - Park, Duk Woo
AU - Park, Kyoung Min
AU - Lee, Bong Ki
AU - Kim, Young Hak
AU - Song, Jong Min
AU - Han, Ki Hoon
AU - Kang, Duk Hyun
AU - Cheong, Sang Sig
AU - Song, Jae Kwan
AU - Kim, Jae Joong
AU - Park, Seong Wook
AU - Park, Seung Jung
PY - 2006/1
Y1 - 2006/1
N2 - BACKGROUND-: Late stent malapposition (LSM) after drug-eluting stent (DES) implantation has not been evaluated sufficiently in real-world practice. METHODS AND RESULTS-: We evaluated the incidence, mechanisms, predictors, and long-term prognosis of LSM after DES implantation in 557 patients (705 native lesions; sirolimus-eluting stent in 538 lesions and paclitaxel-eluting stent in 167 lesions) in whom intravascular ultrasound was performed at index and 6-month follow-up. LSM occurred in 82 patients with 85 lesions (12.1% overall, 95% CI 9.7% to 14.5%, 71 lesions (13.2%) in sirolimus-eluting stents and 14 lesions [8.4%] in paclitaxel-eluting stents, P=0.12]; the incidence was 25.0% (4/16) after directional coronary atherectomy before stenting, 27.5% (14/51) in chronic total occlusion lesions, and 31.8% (7/22) after primary stenting in acute myocardial infarction (P=0.13, P<0.001, and P=0.001, respectively, versus elective stenting with conventional balloon predilation, 9.7% [60/616]). There was an increase of external elastic membrane area (from 17.1±3.6 to 21.4±4.8 mm2, P<0.001) that was greater than the increase in plaque area (from 9.3±2.5 to 10.5±2.7 mm2, P<0.001). Independent predictors of LSM were total stent length, primary stenting in acute myocardial infarction, and chronic total occlusion lesions. Except for 1 death in the non-LSM group, there were no major adverse cardiac events in either LSM or non-LSM patients during a mean 10-month follow-up after detection of LSM. CONCLUSIONS-: LSM occurs in 12% of cases after DES implantation. The predictors of LSM are total stent length, primary stenting in acute myocardial infarction, and chronic total occlusion lesions. LSM after DES implantation was not associated with any major adverse cardiac events during a subsequent 10-month (mean) follow-up.
AB - BACKGROUND-: Late stent malapposition (LSM) after drug-eluting stent (DES) implantation has not been evaluated sufficiently in real-world practice. METHODS AND RESULTS-: We evaluated the incidence, mechanisms, predictors, and long-term prognosis of LSM after DES implantation in 557 patients (705 native lesions; sirolimus-eluting stent in 538 lesions and paclitaxel-eluting stent in 167 lesions) in whom intravascular ultrasound was performed at index and 6-month follow-up. LSM occurred in 82 patients with 85 lesions (12.1% overall, 95% CI 9.7% to 14.5%, 71 lesions (13.2%) in sirolimus-eluting stents and 14 lesions [8.4%] in paclitaxel-eluting stents, P=0.12]; the incidence was 25.0% (4/16) after directional coronary atherectomy before stenting, 27.5% (14/51) in chronic total occlusion lesions, and 31.8% (7/22) after primary stenting in acute myocardial infarction (P=0.13, P<0.001, and P=0.001, respectively, versus elective stenting with conventional balloon predilation, 9.7% [60/616]). There was an increase of external elastic membrane area (from 17.1±3.6 to 21.4±4.8 mm2, P<0.001) that was greater than the increase in plaque area (from 9.3±2.5 to 10.5±2.7 mm2, P<0.001). Independent predictors of LSM were total stent length, primary stenting in acute myocardial infarction, and chronic total occlusion lesions. Except for 1 death in the non-LSM group, there were no major adverse cardiac events in either LSM or non-LSM patients during a mean 10-month follow-up after detection of LSM. CONCLUSIONS-: LSM occurs in 12% of cases after DES implantation. The predictors of LSM are total stent length, primary stenting in acute myocardial infarction, and chronic total occlusion lesions. LSM after DES implantation was not associated with any major adverse cardiac events during a subsequent 10-month (mean) follow-up.
UR - http://www.scopus.com/inward/record.url?scp=33644861134&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33644861134&partnerID=8YFLogxK
U2 - 10.1161/CIRCULATIONAHA.105.563403
DO - 10.1161/CIRCULATIONAHA.105.563403
M3 - Article
C2 - 16432073
AN - SCOPUS:33644861134
SN - 0009-7322
VL - 113
SP - 414
EP - 419
JO - Circulation
JF - Circulation
IS - 3
ER -