Abstract
Neodymium:YAG (Nd:YAG) goniopuncture is an efficient and safe treatment for low filtration through the trabeculo-Descemet's membrane after deep sclerectomy with a collagen implant (DSCI). The only reported complication of this procedure is choroidal detachment. However, we found an iris synechia in a patient whose intraocular pressure (IOP) was elevated again 1 month after Nd:YAG goniopuncture. Synechiolysis and peripheral iridectomy with Nd:YAG and argon lasers effectively removed the iris synechia, and IOP immediately dropped to the normal range. We believe that iris synechia is a potential complication that may cause elevated IOP after laser goniopuncture in patients having DSCI.
Original language | English |
---|---|
Pages (from-to) | 900-902 |
Number of pages | 3 |
Journal | Journal of cataract and refractive surgery |
Volume | 28 |
Issue number | 5 |
DOIs | |
Publication status | Published - 2002 |
All Science Journal Classification (ASJC) codes
- Surgery
- Ophthalmology
- Sensory Systems