TY - JOUR
T1 - Improved multi-echo gradient echo myelin water fraction mapping using complex-valued neural network analysis
AU - Jung, Soozy
AU - Yun, Ji Su
AU - Kim, Deog Young
AU - Kim, Dong Hyun
N1 - Publisher Copyright:
© 2022 International Society for Magnetic Resonance in Medicine.
PY - 2022/7
Y1 - 2022/7
N2 - Purpose: Previously, an artificial neural network method was introduced to estimate quantitative myelin water fraction (MWF) using multi-echo gradient-echo data. However, the fiber orientation of white matter with respect to B0 could bias the quantification of MWF. Here, we developed an advanced workflow for MWF estimation that could improve the quantification of MWF. Methods: To adopt fiber orientation effects, a complex-valued neural network with complex-valued operation was used. In addition, to compensate for the bias from different scan parameters, a signal model incorporating the T1 value was devised for training data generation. At the testing stage, a voxel-spread function approach was utilized for spatial B0 artifact correction. Finally, dropout-based variational inference was implemented for uncertainty estimates on the network model to provide a confidence interpretation of the output. Results: According to simulation and in vivo analysis, the proposed method suggests improved quality of MWF estimation by correcting the bias and artifacts. The proposed complex-valued neural network approach can alleviate the dependency of fiber orientation effects compared to previous artificial neural network method. Uncertainty estimates provides information different from fitting error that can be used as a confidence level of the resulting MWF values. Conclusion: An improved MWF mapping using complex-valued neural network analysis has been proposed.
AB - Purpose: Previously, an artificial neural network method was introduced to estimate quantitative myelin water fraction (MWF) using multi-echo gradient-echo data. However, the fiber orientation of white matter with respect to B0 could bias the quantification of MWF. Here, we developed an advanced workflow for MWF estimation that could improve the quantification of MWF. Methods: To adopt fiber orientation effects, a complex-valued neural network with complex-valued operation was used. In addition, to compensate for the bias from different scan parameters, a signal model incorporating the T1 value was devised for training data generation. At the testing stage, a voxel-spread function approach was utilized for spatial B0 artifact correction. Finally, dropout-based variational inference was implemented for uncertainty estimates on the network model to provide a confidence interpretation of the output. Results: According to simulation and in vivo analysis, the proposed method suggests improved quality of MWF estimation by correcting the bias and artifacts. The proposed complex-valued neural network approach can alleviate the dependency of fiber orientation effects compared to previous artificial neural network method. Uncertainty estimates provides information different from fitting error that can be used as a confidence level of the resulting MWF values. Conclusion: An improved MWF mapping using complex-valued neural network analysis has been proposed.
KW - artificial neural network
KW - multi-echo gradient echo
KW - myelin water fraction
KW - uncertainty
UR - https://www.scopus.com/pages/publications/85125912706
UR - https://www.scopus.com/inward/citedby.url?scp=85125912706&partnerID=8YFLogxK
U2 - 10.1002/mrm.29192
DO - 10.1002/mrm.29192
M3 - Comment/debate
C2 - 35225373
AN - SCOPUS:85125912706
SN - 0740-3194
VL - 88
SP - 492
EP - 500
JO - Magnetic Resonance in Medicine
JF - Magnetic Resonance in Medicine
IS - 1
ER -