Impact of current smoking on 2-year clinical outcomes between durable-polymer-coated stents and biodegradable-polymer-coated stents in acute myocardial infarction after successful percutaneous coronary intervention: Data from the KAMIR

Yong Hoon Kim, Ae Young Her, Myung Ho Jeong, Byeong Keuk Kim, Sung Jin Hong, Dong Ho Shin, Jung Sun Kim, Young Guk Ko, Donghoon Choi, Myeong Ki Hong, Yangsoo Jang

Research output: Contribution to journalArticlepeer-review

9 Citations (Scopus)

Abstract

Objective Data concerning the effect of current smoking on solely new-generation drug-eluting stents (DES) are limited. We investigated the impact of current smoking on 2-year clinical outcomes between durable-polymer (DP)-coated DES (zotarolimus-eluting [ZES] and everolimus eluting [EES]) and biodegradable-polymer (BP)-coated biolimus-eluting stent (BES) in acute myocardial infarction (AMI) patients after successful percutaneous coronary intervention (PCI). Methods Finally, a total of 8357 AMI patients with current smoking underwent successful PCI with new-generation DES (ZES, EES, and BES) were enrolled and divided into three groups as ZES (n = 3199), EES (n = 3987), and BES group (n = 1171). The primary endpoint was the occurrence of major adverse cardiac events (MACE) defined as all-cause death (cardiac death [CD] or non-cardiac death), recurrent AMI (re-MI), any revascularization (target lesion revascularization [TLR], target vessel revascularization [TVR], and non-TVR). The secondary endpoint was the incidence of definite or probable stent thrombosis (ST). Results The 2-year adjusted hazard ratio (HR) of MACE for ZES vs. EES (1.055; 95% confidence interval [CI], 0.843-1.321; p = 0.638), ZES vs. BES (HR, 0.885; 95% CI, 0.626-1.251; p = 0.488), EES vs. BES (HR, 0.889; 95% CI, 0.633-1.250; p = 0.499), and ZES/EES vs. BES (HR, 0.891; 95% CI, 0.648-1.126; p = 0.480) were similar. The occurrence of ST after adjustment were also comparable. In addition, the 2-year adjusted HR for all-cause death, CD, re-MI, TLR, TVR, and non-TVR were not different. Conclusions In this study, DP-DES and BP-DES showed comparable safety and efficacy during 2-year follow-up periods. Therefore, DP-DES or BP-DES are equally acceptable in AMI patients with current smoking undergoing PCI.

Original languageEnglish
Article numbere0205046
JournalPloS one
Volume13
Issue number10
DOIs
Publication statusPublished - 2018 Oct

Bibliographical note

Publisher Copyright:
© 2018 Kim et al.

All Science Journal Classification (ASJC) codes

  • General

Fingerprint

Dive into the research topics of 'Impact of current smoking on 2-year clinical outcomes between durable-polymer-coated stents and biodegradable-polymer-coated stents in acute myocardial infarction after successful percutaneous coronary intervention: Data from the KAMIR'. Together they form a unique fingerprint.

Cite this