Impact of coronary plaque characteristics on late stent malapposition after drug-eluting stent implantation

Sung Jin Hong, Byeong Keuk Kim, Dong Ho Shin, Jung Sun Kim, Young Guk Ko, Donghoon Choi, Yangsoo Jang, Myeong Ki Hong

Research output: Contribution to journalArticlepeer-review

2 Citations (Scopus)

Abstract

Purpose: To evaluate the impact of pre-procedural coronary plaque composition assessed by virtual histology intravascular ultrasound (VH-IVUS) on late stent malapposition assessed by optical coherence tomography (OCT) following drug-eluting stent (DES) implantation. Materials and Methods: The study population consisted of 121 patients (121 lesions) who underwent both pre-procedural VHIVUS and follow-up OCT after DES implantation. The association between pre-procedural plaque composition [necrotic core (NC), dense calcium (DC), fibrotic (FT), and fibro-fatty (FF) volumes] assessed by VH-IVUS and late stent malapposition (percent malapposed struts) or strut coverage (percent uncovered struts) assessed by follow-up OCT was evaluated. Results: Pre-procedural absolute total NC, DC, FT, and FF plaque volumes were 22.9±19.0, 7.9±9.6, 63.8±33.8, and 16.5±12.4 mm3, respectively. At 6.3±3.1 months post-intervention, percent malapposed and uncovered struts were 0.8±2.5% and 15.3±16.7%, respectively. Pre-procedural absolute total NC and DC plaque volumes were positively correlated with percent malapposed struts (r=0.44, p<0.001 and r=0.45, p<0.001, respectively), while pre-procedural absolute total FT plaque volume was weakly associated with percent malapposed struts (r=0.220, p=0.015). Pre-procedural absolute total DC plaque volume was the only independent predictor of late stent malapposition on multivariate analysis (β=1.12, p=0.002). There were no significant correlations between pre-intervention plaque composition and percent uncovered struts. Conclusion: Pre-procedural plaque composition was associated with late stent malapposition but not strut coverage after DES implantation. Larger pre-procedural absolute total DC plaque volumes were associated with greater late stent malapposition.

Original languageEnglish
Pages (from-to)1538-1544
Number of pages7
JournalYonsei medical journal
Volume56
Issue number6
DOIs
Publication statusPublished - 2015 Nov

Bibliographical note

Publisher Copyright:
© Yonsei University College of Medicine 2015.

All Science Journal Classification (ASJC) codes

  • Medicine(all)

Fingerprint

Dive into the research topics of 'Impact of coronary plaque characteristics on late stent malapposition after drug-eluting stent implantation'. Together they form a unique fingerprint.

Cite this