TY - JOUR
T1 - Immediate results and late clinical outcomes after new CrossFlex coronary stent implantation
AU - Park, Seung Jung
AU - Park, Seong Wook
AU - Lee, Cheol Whan
AU - Hong, Myeong Ki
AU - Kim, Jae Joong
AU - Park, Hoon Ki
AU - Hong, Mun K.
AU - Mintz, Gary S.
AU - Leon, Martin B.
PY - 1999/2/15
Y1 - 1999/2/15
N2 - This study evaluates the safety and efficacy of the new CrossFlex stent in the treatment of native coronary artery disease. The CrossFlex stent is a flexible, balloon-expandable new device with an excellent flexibility, radial strength, conformability, and radio-opacity. Little data are available concerning the clinical and angiographic outcomes of this device. The CrossFlex stent was implanted in 209 consecutive patients with 226 lesions. Follow-up angiography was performed at 6 months, and clinical evaluation was undertaken at regular intervals after stent implantation. Procedural success was achieved in all lesions without in-hospital complications. Angiographic follow-up data were available in 153 of the 187 eligible lesions (follow-up rate, 82%), and the overall angiographic restenosis rate was 16.3%. Minimal lumen diameter immediately after stent placement was the only predictor of angiographic restenosis. Clinical follow-up was obtained in all patients at 10.5 ± 5.2 months. There were 4 deaths (1 cardiac in origin, the others noncardiac in origin), and 1 nonfatal myocardial infarction (nonstented artery) during follow-up. Target lesion revascularization was required in 15 patients (7%), and the overall event-free survival rate (death, myocardial infarction, and repeat revascularization) was 87% at the end of the follow- up period. The CrossFlex stent is a safe and effective device with a high procedural success rate, and a favorable late clinical outcome for treatment of native coronary artery disease. Further randomized trials are needed to compare the CrossFlex stent with standard slotted-tube stents.
AB - This study evaluates the safety and efficacy of the new CrossFlex stent in the treatment of native coronary artery disease. The CrossFlex stent is a flexible, balloon-expandable new device with an excellent flexibility, radial strength, conformability, and radio-opacity. Little data are available concerning the clinical and angiographic outcomes of this device. The CrossFlex stent was implanted in 209 consecutive patients with 226 lesions. Follow-up angiography was performed at 6 months, and clinical evaluation was undertaken at regular intervals after stent implantation. Procedural success was achieved in all lesions without in-hospital complications. Angiographic follow-up data were available in 153 of the 187 eligible lesions (follow-up rate, 82%), and the overall angiographic restenosis rate was 16.3%. Minimal lumen diameter immediately after stent placement was the only predictor of angiographic restenosis. Clinical follow-up was obtained in all patients at 10.5 ± 5.2 months. There were 4 deaths (1 cardiac in origin, the others noncardiac in origin), and 1 nonfatal myocardial infarction (nonstented artery) during follow-up. Target lesion revascularization was required in 15 patients (7%), and the overall event-free survival rate (death, myocardial infarction, and repeat revascularization) was 87% at the end of the follow- up period. The CrossFlex stent is a safe and effective device with a high procedural success rate, and a favorable late clinical outcome for treatment of native coronary artery disease. Further randomized trials are needed to compare the CrossFlex stent with standard slotted-tube stents.
UR - http://www.scopus.com/inward/record.url?scp=0033557543&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0033557543&partnerID=8YFLogxK
U2 - 10.1016/S0002-9149(98)00903-5
DO - 10.1016/S0002-9149(98)00903-5
M3 - Article
C2 - 10073851
AN - SCOPUS:0033557543
SN - 0002-9149
VL - 83
SP - 502
EP - 506
JO - American Journal of Cardiology
JF - American Journal of Cardiology
IS - 4
ER -