TY - GEN
T1 - Heat transfer characteristics of an angled array impinging jet on a concave duct
AU - Jung, Eui Yeop
AU - Park, Chan Ung
AU - Lee, Dong Hyun
AU - Kim, Kyung Min
AU - Woo, Ta Kwan
AU - Cho, Hyung Hee
PY - 2012
Y1 - 2012
N2 - This study investigated the heat transfer characteristics of an array jet cooling system on a concave surface. Two types of injection holes were used: one for impinging jets normal to the impingement surface, and the other for angled impinging jets. For the normal jets, the jet Reynolds number (Re) based on the hole diameter varied from 3,000 to 10,000, and the heightto- diameter ratio (H/d) was fixed at 1.0. There were 15 injection holes positioned in a staggered 3×5 array. For the angled jets, Re was set to 5,000 and H/d was also fixed at 1.0. Naphthalene sublimation method was used to determine the heat transfer coefficients on the targeted plates. For normal impinging jet cooling, separate peaks were observed at the stagnation regions due to the curvature effect. Since a crossflow was generated by air spent from the jet arrays, the crossflow effect increased as it moved downstream. Due to the interaction between the crossflow and impinging jets, the peak values at the stagnation points increased downstream. The heat transfer coefficient on the targeted plate increased with Re. The average Sh of the angled jets was higher than that of the normal jets, as the obliquely impinging jet increased the mass flow rate and mass interaction between the jet impingement points.
AB - This study investigated the heat transfer characteristics of an array jet cooling system on a concave surface. Two types of injection holes were used: one for impinging jets normal to the impingement surface, and the other for angled impinging jets. For the normal jets, the jet Reynolds number (Re) based on the hole diameter varied from 3,000 to 10,000, and the heightto- diameter ratio (H/d) was fixed at 1.0. There were 15 injection holes positioned in a staggered 3×5 array. For the angled jets, Re was set to 5,000 and H/d was also fixed at 1.0. Naphthalene sublimation method was used to determine the heat transfer coefficients on the targeted plates. For normal impinging jet cooling, separate peaks were observed at the stagnation regions due to the curvature effect. Since a crossflow was generated by air spent from the jet arrays, the crossflow effect increased as it moved downstream. Due to the interaction between the crossflow and impinging jets, the peak values at the stagnation points increased downstream. The heat transfer coefficient on the targeted plate increased with Re. The average Sh of the angled jets was higher than that of the normal jets, as the obliquely impinging jet increased the mass flow rate and mass interaction between the jet impingement points.
UR - http://www.scopus.com/inward/record.url?scp=84881151209&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84881151209&partnerID=8YFLogxK
U2 - 10.1115/GT2012-69566
DO - 10.1115/GT2012-69566
M3 - Conference contribution
AN - SCOPUS:84881151209
SN - 9780791844700
T3 - Proceedings of the ASME Turbo Expo
SP - 601
EP - 607
BT - ASME Turbo Expo 2012
T2 - ASME Turbo Expo 2012: Turbine Technical Conference and Exposition, GT 2012
Y2 - 11 June 2012 through 15 June 2012
ER -