Feasibility of using distal endpoints for in-room pet range verification of proton therapy

Kira Grogg, Xuping Zhu, Chul Hee Min, Brian Winey, Thomas Bortfeld, Harald Paganetti, Helen A. Shih, Georges El Fakhri

Research output: Contribution to journalArticlepeer-review

7 Citations (Scopus)

Abstract

In an effort to verify the dose delivery in proton therapy, positron emission tomography (PET) scans have been employed to measure the distribution of \beta+ radioactivity produced from nuclear reactions of the protons with native nuclei. Since the dose and PET distributions are difficult to compare directly, the range verification is currently carried out by comparing measured and Monte Carlo (MC) simulation predicted PET distributions. In order to reduce the reliance on MC, simulated PET (simPET) and dose distal endpoints were compared to explore the feasibility of using distal endpoints for in-room PET range verification. MC simulations were generated for six head and neck patients with corrections for radiological decay, biological washout, and PET resolution. One-dimensional profiles of the dose and simPET were examined along the direction of the beam and covering the cross section of the beam. The chosen endpoints of the simPET (x-intercept of the linear fit to the distal falloff) and planned dose (20%-50% of maximum dose) correspond to where most of the protons are below the threshold energy for the nuclear reactions. The difference in endpoint range between the distal surfaces of the dose and MC-PET were compared and the spread of range differences was assessed. Among the six patients, the mean difference between MC-PET and dose depth was found to be -1.6 mm to +0.5 mm between patients, with a standard deviation of 1.1 to 4.0 mm across the individual beams. In clinical practice, regions with deviations beyond the safety margin need to be examined more closely and can potentially lead to adjustments to the treatment plan.

Original languageEnglish
Article number6596511
Pages (from-to)3290-3297
Number of pages8
JournalIEEE Transactions on Nuclear Science
Volume60
Issue number5
DOIs
Publication statusPublished - 2013

All Science Journal Classification (ASJC) codes

  • Nuclear and High Energy Physics
  • Nuclear Energy and Engineering
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Feasibility of using distal endpoints for in-room pet range verification of proton therapy'. Together they form a unique fingerprint.

Cite this