TY - JOUR
T1 - Feasibility of Aortic Annular Measurements Using Noncontrast-Enhanced Cardiac Computed Tomography in Preprocedural Evaluation of Transcatheter Aortic Valve Replacement
T2 - A Comparison with Contrast-Enhanced Computed Tomography
AU - Suh, Young Joo
AU - Lee, Sak
AU - Hong, Geu Ru
AU - Ko, Young Guk
AU - Hong, Myeong Ki
AU - Kim, Young Jin
N1 - Publisher Copyright:
© Wolters Kluwer Health, Inc. All rights reserved.
PY - 2022/2/1
Y1 - 2022/2/1
N2 - Objective Noncontrast-enhanced (NCE) cross-sectional images other than contrast-enhanced (CE)-computed tomography (CT) may be necessary for annular sizing before transcatheter aortic valve replacement (TAVR), because of the risk of contrast-induced nephropathy. We aimed to investigate the feasibility of aortic annular measurements using NCE-CT in TAVR candidates by comparing them with CE-CT measurements. Methods We retrospectively enrolled 46 patients who underwent CT for the purpose of pre-TAVR evaluation (17 men; mean age, 82.3 ± 5.0 years). On CE and NCE examination, measurements of the average diameter and perimeter of aortic annulus were performed by 2 observers, and coronary ostial heights were measured. Differences in annular parameters and coronary ostial heights between NCE and CE examinations were assessed using Bland-Altman analysis and intraclass correlation coefficients (ICCs). Results Aortic annulus measurement values were significantly larger in the NCE examinations compared with those in the CE examinations according to both readers (mean differences of 0.8 mm for the average diameter and 2.1 mm for the perimeter according to observer 1, and 1.1 mm for the average diameter and 3.4 mm for the perimeter according to observer 2; ICC, 0.771-0.923). The mean difference between coronary ostial height measurement on NCE and CE examination was 0.6 mm for left coronary ostium (ICC, 0.795) and 0.7 mm for right coronary ostium (ICC, 0.802). No case showed disagreement between NCE and CE examinations for hypothetical valve sizing. Conclusions Noncontrast-enhanced cardiac CT examination may be feasible for aortic annular measurements before TAVR and provides comparable measurement values to CE examination.
AB - Objective Noncontrast-enhanced (NCE) cross-sectional images other than contrast-enhanced (CE)-computed tomography (CT) may be necessary for annular sizing before transcatheter aortic valve replacement (TAVR), because of the risk of contrast-induced nephropathy. We aimed to investigate the feasibility of aortic annular measurements using NCE-CT in TAVR candidates by comparing them with CE-CT measurements. Methods We retrospectively enrolled 46 patients who underwent CT for the purpose of pre-TAVR evaluation (17 men; mean age, 82.3 ± 5.0 years). On CE and NCE examination, measurements of the average diameter and perimeter of aortic annulus were performed by 2 observers, and coronary ostial heights were measured. Differences in annular parameters and coronary ostial heights between NCE and CE examinations were assessed using Bland-Altman analysis and intraclass correlation coefficients (ICCs). Results Aortic annulus measurement values were significantly larger in the NCE examinations compared with those in the CE examinations according to both readers (mean differences of 0.8 mm for the average diameter and 2.1 mm for the perimeter according to observer 1, and 1.1 mm for the average diameter and 3.4 mm for the perimeter according to observer 2; ICC, 0.771-0.923). The mean difference between coronary ostial height measurement on NCE and CE examination was 0.6 mm for left coronary ostium (ICC, 0.795) and 0.7 mm for right coronary ostium (ICC, 0.802). No case showed disagreement between NCE and CE examinations for hypothetical valve sizing. Conclusions Noncontrast-enhanced cardiac CT examination may be feasible for aortic annular measurements before TAVR and provides comparable measurement values to CE examination.
KW - computed tomography
KW - contrast-enhanced
KW - noncontrast-enhanced
KW - preprocedural planning
KW - transcatheter aortic valve replacement
UR - http://www.scopus.com/inward/record.url?scp=85123905851&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85123905851&partnerID=8YFLogxK
U2 - 10.1097/RCT.0000000000001238
DO - 10.1097/RCT.0000000000001238
M3 - Article
C2 - 35099136
AN - SCOPUS:85123905851
SN - 0363-8715
VL - 46
SP - 50
EP - 55
JO - Journal of Computer Assisted Tomography
JF - Journal of Computer Assisted Tomography
IS - 1
ER -