Abstract
This study evaluated the possible clinical application of low-intensity ultrasound (LIUS) stimulation for preventing osteoporotic bone fracture. Eight virgin 14-week-old ICR mice (weight 24.0 ± 0.7 g) were ovariectomized to induce osteoporosis. The right hind limbs (US limbs) were stimulated with LIUS, whereas the left hind limbs (CON limbs) were not stimulated. LIUS was applied for 20 min a day, 5 days a week over a 6-week period using the following parameters: 1.5 MHz frequency, 1.0 kHz pulse repetition, 30 mW/cm2 intensity, and 200 ls pulse length. The effective structural modulus increased significantly (p>0.05) in the US limbs over time with the increased bone quantity, whereas that in CON limbs remained statistically constant (p<0.05). In addition, the elastic modulus in the US limbs was generally enhanced by an increased bone quality, compared with the CON limbs. Therefore, LIUS stimulation may effectively reduce the risk of osteoporotic bone fracture by increasing the mechanical characteristics of bone via improvements in both the effective structural and elastic modulus of the osteoporotic bone. In conclusion, LIUS may potentially prove very effective clinically for preventing osteoporotic bone fractures.
Original language | English |
---|---|
Pages (from-to) | 2438-2446 |
Number of pages | 9 |
Journal | Annals of Biomedical Engineering |
Volume | 38 |
Issue number | 7 |
DOIs | |
Publication status | Published - 2010 Jul |
Bibliographical note
Funding Information:This study was supported by a grant of the Korea Healthcare technology R&D Project, Ministry for Health, Welfare &Family Affairs, Republic of Korea (A080920).
All Science Journal Classification (ASJC) codes
- Biomedical Engineering