TY - JOUR
T1 - Establishing quality control ranges for antimicrobial susceptibility testing of Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus
T2 - A cornerstone to develop reference strains for Korean clinical microbiology laboratories
AU - Hong, Sung Kuk
AU - Choi, Seung Jun
AU - Shin, Saeam
AU - Lee, Wonmok
AU - Pinto, Naina
AU - Shin, Nari
AU - Lee, Kwangjun
AU - Hong, Seong Geun
AU - Kim, Young Ah
AU - Lee, Hyukmin
AU - Kim, Heejung
AU - Song, Wonkeun
AU - Lee, Sun Hwa
AU - Yong, Dongeun
AU - Lee, Kyungwon
AU - Chong, Yunsop
N1 - Publisher Copyright:
© The Korean Society for Laboratory Medicine.
PY - 2015/11/1
Y1 - 2015/11/1
N2 - Quality control (QC) processes are being performed in the majority of clinical microbiology laboratories to ensure the performance of microbial identification and antimicrobial susceptibility testing by using ATCC strains. To obtain these ATCC strains, some inconveniences are encountered concerning the purchase cost of the strains and the shipping time required. This study was focused on constructing a database of reference strains for QC processes using domestic bacterial strains, concentrating primarily on antimicrobial susceptibility testing. Three strains (Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus) that showed legible results in preliminary testing were selected. The minimal inhibitory concentrations (MICs) and zone diameters (ZDs) of eight antimicrobials for each strain were determined according to the CLSI M23. All resulting MIC and ZD ranges included at least 95% of the data. The ZD QC ranges obtained by using the CLSI method were less than 12 mm, and the MIC QC ranges extended no more than five dilutions. This study is a preliminary attempt to construct a bank of Korean QC strains. With further studies, a positive outcome toward cost and time reduction can be anticipated.
AB - Quality control (QC) processes are being performed in the majority of clinical microbiology laboratories to ensure the performance of microbial identification and antimicrobial susceptibility testing by using ATCC strains. To obtain these ATCC strains, some inconveniences are encountered concerning the purchase cost of the strains and the shipping time required. This study was focused on constructing a database of reference strains for QC processes using domestic bacterial strains, concentrating primarily on antimicrobial susceptibility testing. Three strains (Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus) that showed legible results in preliminary testing were selected. The minimal inhibitory concentrations (MICs) and zone diameters (ZDs) of eight antimicrobials for each strain were determined according to the CLSI M23. All resulting MIC and ZD ranges included at least 95% of the data. The ZD QC ranges obtained by using the CLSI method were less than 12 mm, and the MIC QC ranges extended no more than five dilutions. This study is a preliminary attempt to construct a bank of Korean QC strains. With further studies, a positive outcome toward cost and time reduction can be anticipated.
UR - http://www.scopus.com/inward/record.url?scp=84942247345&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84942247345&partnerID=8YFLogxK
U2 - 10.3343/alm.2015.35.6.635
DO - 10.3343/alm.2015.35.6.635
M3 - Article
C2 - 26354353
AN - SCOPUS:84942247345
SN - 2234-3806
VL - 35
SP - 635
EP - 638
JO - Annals of laboratory medicine
JF - Annals of laboratory medicine
IS - 6