TY - JOUR
T1 - Empirical investigation of occupant-centric thermal comfort in hotel guestrooms
AU - Lee, Junsoo
AU - Cha, Seung Hyun
AU - Hong, Taehoon
AU - Koo, Choongwan
N1 - Publisher Copyright:
© 2023 Elsevier Ltd
PY - 2024/1
Y1 - 2024/1
N2 - Given the importance of occupant satisfaction with thermal comfort in hotel accommodations, previous studies have assessed thermal comfort using either local or global standards. In a hotel catering to diverse guests, a single standard may constrain the formulation of an optimal strategy for improving occupant satisfaction. To address this challenge, this study empirically investigates occupant-centric thermal comfort in hotel guestrooms located in a hot and humid climatic region. To this end, a living-lab-based case study was conducted on a hotel guestroom in Hong Kong, wherein two types of thermal comfort improvement strategies were devised from both local and global perspectives. First, to improve thermal comfort in line with the local standard, it was determined that an ancillary fan coil unit (FCU) energy consumption of 6.0 kW h (approximately 34 % of the existing energy consumption) was required. Second, to improve thermal comfort in line with the global standard, an ancillary FCU energy consumption of 9.4 kW h (approximately 53 % of the existing energy consumption) was necessary. Consequently, in a hot and humid climatic region, the distribution of thermal comfort may vary depending on the type of guest (e.g., domestic or foreign), and ancillary cooling energy expenditure may be incurred to enhance a guest's thermal comfort. The proposed approach is expected to contribute to the creation of occupant-tailored thermal comfort by considering an individual's thermal acclimation to a specific climatic region from both local and global perspectives.
AB - Given the importance of occupant satisfaction with thermal comfort in hotel accommodations, previous studies have assessed thermal comfort using either local or global standards. In a hotel catering to diverse guests, a single standard may constrain the formulation of an optimal strategy for improving occupant satisfaction. To address this challenge, this study empirically investigates occupant-centric thermal comfort in hotel guestrooms located in a hot and humid climatic region. To this end, a living-lab-based case study was conducted on a hotel guestroom in Hong Kong, wherein two types of thermal comfort improvement strategies were devised from both local and global perspectives. First, to improve thermal comfort in line with the local standard, it was determined that an ancillary fan coil unit (FCU) energy consumption of 6.0 kW h (approximately 34 % of the existing energy consumption) was required. Second, to improve thermal comfort in line with the global standard, an ancillary FCU energy consumption of 9.4 kW h (approximately 53 % of the existing energy consumption) was necessary. Consequently, in a hot and humid climatic region, the distribution of thermal comfort may vary depending on the type of guest (e.g., domestic or foreign), and ancillary cooling energy expenditure may be incurred to enhance a guest's thermal comfort. The proposed approach is expected to contribute to the creation of occupant-tailored thermal comfort by considering an individual's thermal acclimation to a specific climatic region from both local and global perspectives.
KW - A hot and humid climate
KW - Ancillary cooling energy expenditure
KW - Hotel guestrooms
KW - Local and global standards
KW - Thermal acclimatization
KW - Thermal comfort
UR - http://www.scopus.com/inward/record.url?scp=85177788948&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85177788948&partnerID=8YFLogxK
U2 - 10.1016/j.rser.2023.114046
DO - 10.1016/j.rser.2023.114046
M3 - Article
AN - SCOPUS:85177788948
SN - 1364-0321
VL - 189
JO - Renewable and Sustainable Energy Reviews
JF - Renewable and Sustainable Energy Reviews
M1 - 114046
ER -