TY - JOUR
T1 - Effects of recycling on the biomechanical characteristics of retrieved orthodontic miniscrews
AU - Yun, Soon Dong
AU - Choi, Sung Hwan
AU - Cha, Jung Yul
AU - Yu, Hyung Seog
AU - Kim, Kwang Mahn
AU - Kim, Jin
AU - Hwang, Chung Ju
N1 - Publisher Copyright:
© 2017 The Korean Association of Orthodontists.
PY - 2017/7
Y1 - 2017/7
N2 - Objective: The aim of this study was to compare recycled and unused orthodontic miniscrews to determine the feasibility of reuse. The comparisons included both miniscrews with machined surfaces (MS), and those with etched surfaces (ES). Methods: Retrieved MS and ES were further divided into three subgroups according to the assigned recycling procedure: group A, air-water spray; group B, mechanical cleaning; and group C, mechanical and chemical cleaning. Unused screws were used as controls. Scanning electron microscopy, energy-dispersive X-ray spectrometry, insertion time and maximum insertion torque measurements in artificial bone, and biological responses in the form of periotest values (PTV), bone-implant contact ratio (BIC), and bone volume ratio (BV) were assessed. Results: Morphological changes after recycling mainly occurred at the screw tip, and the cortical bone penetration success rate of recycled screws was lower than that of unused screws. Retrieved ES needed more thorough cleaning than retrieved MS to produce a surface composition similar to that of unused screws. There were no significant differences in PTV or BIC between recycled and unused screws, while the BV of the former was significantly lower than that of the latter (p < 0.05). Conclusions: These results indicate that reuse of recycled orthodontic miniscrews may not be feasible from the biomechanical aspect.
AB - Objective: The aim of this study was to compare recycled and unused orthodontic miniscrews to determine the feasibility of reuse. The comparisons included both miniscrews with machined surfaces (MS), and those with etched surfaces (ES). Methods: Retrieved MS and ES were further divided into three subgroups according to the assigned recycling procedure: group A, air-water spray; group B, mechanical cleaning; and group C, mechanical and chemical cleaning. Unused screws were used as controls. Scanning electron microscopy, energy-dispersive X-ray spectrometry, insertion time and maximum insertion torque measurements in artificial bone, and biological responses in the form of periotest values (PTV), bone-implant contact ratio (BIC), and bone volume ratio (BV) were assessed. Results: Morphological changes after recycling mainly occurred at the screw tip, and the cortical bone penetration success rate of recycled screws was lower than that of unused screws. Retrieved ES needed more thorough cleaning than retrieved MS to produce a surface composition similar to that of unused screws. There were no significant differences in PTV or BIC between recycled and unused screws, while the BV of the former was significantly lower than that of the latter (p < 0.05). Conclusions: These results indicate that reuse of recycled orthodontic miniscrews may not be feasible from the biomechanical aspect.
UR - http://www.scopus.com/inward/record.url?scp=85026474824&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85026474824&partnerID=8YFLogxK
U2 - 10.4041/kjod.2017.47.4.238
DO - 10.4041/kjod.2017.47.4.238
M3 - Article
AN - SCOPUS:85026474824
SN - 2234-7518
VL - 47
SP - 238
EP - 247
JO - Korean Journal of Orthodontics
JF - Korean Journal of Orthodontics
IS - 4
ER -