N2 - The lack of an effective detection method for lung circulating tumor cells (CTCs) presents a substantial challenge to elucidate the value of CTCs as a diagnostic or prognostic indicator in lung cancer, particularly in nonsmall cell lung cancer (NSCLC). In this study, we prepared a capture surface exploiting strong multivalent binding mediated by poly(amidoamine) (PAMAM) dendrimers to capture CTCs originating from lung cancers. Given that 85% of the tumor cells from NSCLC patients overexpress epidermal growth factor receptor (EGFR), anti-EGFR was chosen as a capture agent. Following in vitro confirmation using the murine lung cancer cell lines (ED-1 and ED1-SC), cyclin E-overexpressing (CEO) transgenic mice were employed as an in vivo lung tumor model to assess specificity and sensitivity of the capture surface. The numbers of CTCs in blood from the CEO transgenic mice were significantly higher than those from the healthy controls (on average 75.3 ± 14.9 vs 4.4 ± 1.2 CTCs/100 μL of blood, p < 0.005), indicating the high sensitivity and specificity of our surface. Furthermore, we found that the capture surface also offers a simple, effective method for monitoring treatment responses, as observed by the significant decrease in the CTC numbers from the CEO mice upon a treatment using a novel anti-miR-31 locked nucleic acid (LNA), compared to a vehicle treatment and a control-LNA treatment (p < 0.05). This in vivo evaluation study confirms that our capture surface is highly efficient in detecting in vivo CTCs and thus has translational potential as a diagnostic and prognostic tool for lung cancer.
AB - The lack of an effective detection method for lung circulating tumor cells (CTCs) presents a substantial challenge to elucidate the value of CTCs as a diagnostic or prognostic indicator in lung cancer, particularly in nonsmall cell lung cancer (NSCLC). In this study, we prepared a capture surface exploiting strong multivalent binding mediated by poly(amidoamine) (PAMAM) dendrimers to capture CTCs originating from lung cancers. Given that 85% of the tumor cells from NSCLC patients overexpress epidermal growth factor receptor (EGFR), anti-EGFR was chosen as a capture agent. Following in vitro confirmation using the murine lung cancer cell lines (ED-1 and ED1-SC), cyclin E-overexpressing (CEO) transgenic mice were employed as an in vivo lung tumor model to assess specificity and sensitivity of the capture surface. The numbers of CTCs in blood from the CEO transgenic mice were significantly higher than those from the healthy controls (on average 75.3 ± 14.9 vs 4.4 ± 1.2 CTCs/100 μL of blood, p < 0.005), indicating the high sensitivity and specificity of our surface. Furthermore, we found that the capture surface also offers a simple, effective method for monitoring treatment responses, as observed by the significant decrease in the CTC numbers from the CEO mice upon a treatment using a novel anti-miR-31 locked nucleic acid (LNA), compared to a vehicle treatment and a control-LNA treatment (p < 0.05). This in vivo evaluation study confirms that our capture surface is highly efficient in detecting in vivo CTCs and thus has translational potential as a diagnostic and prognostic tool for lung cancer.
UR - http://www.scopus.com/inward/record.url?scp=84943145653&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84943145653&partnerID=8YFLogxK
U2 - 10.1021/acs.analchem.5b02766
DO - 10.1021/acs.analchem.5b02766
M3 - Article
C2 - 26312815
AN - SCOPUS:84943145653
SN - 0003-2700
VL - 87
SP - 10096
EP - 10102
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 19
ER -