T1 - Effect of rotation on heat/mass transfer for an impingement/effusion cooling system
AU - Hong, Sung Kook
AU - Cho, Hyung Hee
PY - 2007
Y1 - 2007
N2 - The purpose of this study is to investigate the effect of rotation on the heat/mass transfer in an impingement/effusion cooling system. To simulate the rotating impingement/effusion system, a test duct with injection and effusion holes is installed on the rotating system. The jet Reynolds number based on the hole diameter is fixed to 3,000 and the Rotation number is set to 0.032. The experiments are carried out for various parameters such as the plate spacing to hole diameter ratio (H/d), orientation of the jet relative to the rotating axis and the tests for the array jet cooling are performed together. The naphthalene sublimation method is used to obtain the heat/mass transfer coefficients on the effusion plate. The local heat/mass transfer distributions are altered by the rotation. For the impingement/effusion cooling with orthogonal orientation, the low and non-uniform heat/mass transfer occurs between the effusion holes because the impinging jet is deflected by the Coriolis force. At a small H/d, the rotation enhances the heat/mass transfer in the stagnation region due to an increase in flow mixing. The impingement/effusion cooling with H/d=2 shows the most efficient cooling performance and it is confirmed that the crossflow and H/d affect the averaged Sh value significantly under rotating conditions.
AB - The purpose of this study is to investigate the effect of rotation on the heat/mass transfer in an impingement/effusion cooling system. To simulate the rotating impingement/effusion system, a test duct with injection and effusion holes is installed on the rotating system. The jet Reynolds number based on the hole diameter is fixed to 3,000 and the Rotation number is set to 0.032. The experiments are carried out for various parameters such as the plate spacing to hole diameter ratio (H/d), orientation of the jet relative to the rotating axis and the tests for the array jet cooling are performed together. The naphthalene sublimation method is used to obtain the heat/mass transfer coefficients on the effusion plate. The local heat/mass transfer distributions are altered by the rotation. For the impingement/effusion cooling with orthogonal orientation, the low and non-uniform heat/mass transfer occurs between the effusion holes because the impinging jet is deflected by the Coriolis force. At a small H/d, the rotation enhances the heat/mass transfer in the stagnation region due to an increase in flow mixing. The impingement/effusion cooling with H/d=2 shows the most efficient cooling performance and it is confirmed that the crossflow and H/d affect the averaged Sh value significantly under rotating conditions.
UR - http://www.scopus.com/inward/record.url?scp=34548719307&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=34548719307&partnerID=8YFLogxK
U2 - 10.1115/GT2007-27265
DO - 10.1115/GT2007-27265
M3 - Conference contribution
AN - SCOPUS:34548719307
SN - 079184790X
SN - 9780791847909
T3 - Proceedings of the ASME Turbo Expo
SP - 269
EP - 278
BT - Proceedings of the ASME Turbo Expo 2007 - Power for Land, Sea, and Air
T2 - 2007 ASME Turbo Expo
Y2 - 14 May 2007 through 17 May 2007
ER -