Effect of anatomical backgrounds on detectability in volumetric cone beam CT images

Minah Han, Subok Park, Jongduk Baek

Research output: Chapter in Book/Report/Conference proceedingConference contribution

2 Citations (Scopus)

Abstract

As anatomical noise is often a dominating factor affecting signal detection in medical imaging, we investigate the effects of anatomical backgrounds on signal detection in volumetric cone beam CT images. Signal detection performances are compared between transverse and longitudinal planes with either uniform or anatomical backgrounds. Sphere objects with diameters of 1mm, 5mm, 8mm, and 11mm are used as the signals. Three-dimensional (3D) anatomical backgrounds are generated using an anatomical noise power spectrum, 1/fβ, with β=3, equivalent to mammographic background [1]. The mean voxel value of the 3D anatomical backgrounds is used as an attenuation coefficient of the uniform background. Noisy projection data are acquired by the forward projection of the uniform and anatomical 3D backgrounds with/without sphere lesions and by the addition of quantum noise. Then, images are reconstructed by an FDK algorithm [2]. For each signal size, signal detection performances in transverse and longitudinal planes are measured by calculating the task SNR of a channelized Hotelling observer with Laguerre-Gauss channels. In the uniform background case, transverse planes yield higher task SNR values for all sphere diameters but 1mm. In the anatomical background case, longitudinal planes yield higher task SNR values for all signal diameters. The results indicate that it is beneficial to use longitudinal planes to detect spherical signals in anatomical backgrounds.

Original languageEnglish
Title of host publicationMedical Imaging 2016
Subtitle of host publicationImage Perception, Observer Performance, and Technology Assessment
EditorsCraig K. Abbey, Matthew A. Kupinski
PublisherSPIE
ISBN (Electronic)9781510600225
DOIs
Publication statusPublished - 2016
EventMedical Imaging 2016: Image Perception, Observer Performance, and Technology Assessment - San Diego, United States
Duration: 2016 Mar 22016 Mar 3

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume9787
ISSN (Print)1605-7422

Other

OtherMedical Imaging 2016: Image Perception, Observer Performance, and Technology Assessment
Country/TerritoryUnited States
CitySan Diego
Period16/3/216/3/3

Bibliographical note

Publisher Copyright:
© 2016 SPIE.

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Biomaterials
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Effect of anatomical backgrounds on detectability in volumetric cone beam CT images'. Together they form a unique fingerprint.

Cite this