TY - JOUR
T1 - Determination of the distal dose edge in a human phantom by measuring the prompt gamma distribution
T2 - A monte carlo study
AU - Min, Chul Hee
AU - Lee, Han Rim
AU - Yeom, Yeon Su
AU - Cho, Sungkoo
AU - Kim, Chan Hyeong
PY - 2010
Y1 - 2010
N2 - The close relationship between the proton dose distribution and the distribution of prompt gammas generated by proton-induced nuclear interactions along the path of protons in a water phantom was demonstrated by means of both Monte Carlo simulations and limited experiments. In order to test the clinical applicability of the method for determining the distal dose edge in a human body, a human voxel model, constructed based on a body-composition-approximated physical phantom, was used, after which the MCNPX code was used to analyze the energy spectra and the prompt gamma yields from the major elements composing the human voxel model; finally, the prompt gamma distribution, generated from the voxel model and measured by using an array-type prompt gamma detection system, was calculated and compared with the proton dose distribution. According to the results, effective prompt gammas were produced mainly by oxygen, and the specific energy of the prompt gammas, allowing for selective measurement, was found to be 4.44 MeV. The results also show that the distal dose edge in the human phantom, despite the heterogeneous composition and the complicated shape, can be determined by measuring the prompt gamma distribution with an array-type detection system.
AB - The close relationship between the proton dose distribution and the distribution of prompt gammas generated by proton-induced nuclear interactions along the path of protons in a water phantom was demonstrated by means of both Monte Carlo simulations and limited experiments. In order to test the clinical applicability of the method for determining the distal dose edge in a human body, a human voxel model, constructed based on a body-composition-approximated physical phantom, was used, after which the MCNPX code was used to analyze the energy spectra and the prompt gamma yields from the major elements composing the human voxel model; finally, the prompt gamma distribution, generated from the voxel model and measured by using an array-type prompt gamma detection system, was calculated and compared with the proton dose distribution. According to the results, effective prompt gammas were produced mainly by oxygen, and the specific energy of the prompt gammas, allowing for selective measurement, was found to be 4.44 MeV. The results also show that the distal dose edge in the human phantom, despite the heterogeneous composition and the complicated shape, can be determined by measuring the prompt gamma distribution with an array-type detection system.
UR - http://www.scopus.com/inward/record.url?scp=77956376467&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77956376467&partnerID=8YFLogxK
U2 - 10.3938/jkps.56.2059
DO - 10.3938/jkps.56.2059
M3 - Article
AN - SCOPUS:77956376467
SN - 0374-4884
VL - 56
SP - 2059
EP - 2062
JO - Journal of the Korean Physical Society
JF - Journal of the Korean Physical Society
IS - 61
ER -