T1 - Determination of optimal imaging mode for ultrasonographic detection of subdermal contraceptive rods
T2 - Comparison of spatial compound, conventional, and tissue harmonic imaging methods
AU - Kim, Sungjun
AU - Seo, Kyung
AU - Song, Ho Taek
AU - Suh, In Suck
AU - Yoon, Choon Sik
AU - Ryu, Jeong Ah
AU - Park, Jeong Seon
AU - Kim, Ah Hyun
AU - Park, Ah Young
AU - Kim, Yaena
PY - 2012/10
Y1 - 2012/10
N2 - Objective: To determine which mode of ultrasonography (US), among the conventional, spatial compound, and tissue-harmonic methods, exhibits the best performance for the detection of Implanon® with respect to generation of posterior acoustic shadowing (PAS). Materials and Methods: A total of 21 patients, referred for localization of impalpable Implanon®, underwent US, using the three modes with default settings (i.e., wide focal zone). Representative transverse images of the rods, according to each mode for all patients, were obtained. The resulting 63 images were reviewed by four observers. The observers provided a confidence score for the presence of PAS, using a five-point scale ranging from 1 (definitely absent) to 5 (definitely present), with scores of 4 or 5 for PAS being considered as detection. The average scores of PAS, obtained from the three different modes for each observer, were compared using one-way repeated measure ANOVA. The detection rates were compared using a weighted least square method. Results: Statistically, the tissue harmonic mode was significantly superior to the other two modes, when comparing the average scores of PAS for all observers (p < 0.00-1). The detection rate was also highest for the tissue harmonic mode (p < 0.001). Conclusion: Tissue harmonic mode in uS appears to be the most suitable in detecting subdermal contraceptive implant rods.
AB - Objective: To determine which mode of ultrasonography (US), among the conventional, spatial compound, and tissue-harmonic methods, exhibits the best performance for the detection of Implanon® with respect to generation of posterior acoustic shadowing (PAS). Materials and Methods: A total of 21 patients, referred for localization of impalpable Implanon®, underwent US, using the three modes with default settings (i.e., wide focal zone). Representative transverse images of the rods, according to each mode for all patients, were obtained. The resulting 63 images were reviewed by four observers. The observers provided a confidence score for the presence of PAS, using a five-point scale ranging from 1 (definitely absent) to 5 (definitely present), with scores of 4 or 5 for PAS being considered as detection. The average scores of PAS, obtained from the three different modes for each observer, were compared using one-way repeated measure ANOVA. The detection rates were compared using a weighted least square method. Results: Statistically, the tissue harmonic mode was significantly superior to the other two modes, when comparing the average scores of PAS for all observers (p < 0.00-1). The detection rate was also highest for the tissue harmonic mode (p < 0.001). Conclusion: Tissue harmonic mode in uS appears to be the most suitable in detecting subdermal contraceptive implant rods.
UR - http://www.scopus.com/inward/record.url?scp=84866235084&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84866235084&partnerID=8YFLogxK
U2 - 10.3348/kjr.2012.13.5.602
DO - 10.3348/kjr.2012.13.5.602
M3 - Article
C2 - 22977328
AN - SCOPUS:84866235084
SN - 1229-6929
VL - 13
SP - 602
EP - 609
JO - Korean journal of radiology
JF - Korean journal of radiology
IS - 5
ER -