TY - JOUR
T1 - Design and application of an Lnertial Lmpactor in combination with an ATP bioluminescence detector for in situ rapid estimation of the efficacies of air controlling devices on removal of bioaerosols
AU - Yoon, Ki Young
AU - Park, Chul Woo
AU - Byeon, Jeong Hoon
AU - Hwang, Jungho
PY - 2010/3/1
Y1 - 2010/3/1
N2 - We proposed a rapid method to estimate the efficacies of air controlling devices in situ using ATP bioluminescence in combination with an inertial impactor. The inertial impactor was designed to have 1 μm of cutoff diameter, and its performance was estimated analytically, numerically, and experimentally. The proposed method was characterized using Staphylococcus epidermidis, which was aerosolized with a nebulizer. The bioaerosol concentrations were estimated within 25 min using the proposed method without a culturing process, which requires several days for colony formation. A linear relationship was obtained between the results of the proposed ATP method (RLU/m3) and the conventional culture-based method (CFU)/ m 3), with R2 0.9283. The proposed method was applied to estimate the concentration of indoor bioaerosols, which were identified as a mixture of various microbial species including bacteria, fungi, and actinomycetes, in an occupational indoor environment controlled by mechanical ventilation and an air cleaner. Consequently, the proposed method showed a linearity with the culture-based method for indoor bioaerosols with R 2 0.8189, even though various kinds of microorganisms existed in the indoor air. The proposed method may be effective in monitoring the changes of relative concentration of indoor bioaerosols and estimating the effectiveness of air control devices in indoor environments.
AB - We proposed a rapid method to estimate the efficacies of air controlling devices in situ using ATP bioluminescence in combination with an inertial impactor. The inertial impactor was designed to have 1 μm of cutoff diameter, and its performance was estimated analytically, numerically, and experimentally. The proposed method was characterized using Staphylococcus epidermidis, which was aerosolized with a nebulizer. The bioaerosol concentrations were estimated within 25 min using the proposed method without a culturing process, which requires several days for colony formation. A linear relationship was obtained between the results of the proposed ATP method (RLU/m3) and the conventional culture-based method (CFU)/ m 3), with R2 0.9283. The proposed method was applied to estimate the concentration of indoor bioaerosols, which were identified as a mixture of various microbial species including bacteria, fungi, and actinomycetes, in an occupational indoor environment controlled by mechanical ventilation and an air cleaner. Consequently, the proposed method showed a linearity with the culture-based method for indoor bioaerosols with R 2 0.8189, even though various kinds of microorganisms existed in the indoor air. The proposed method may be effective in monitoring the changes of relative concentration of indoor bioaerosols and estimating the effectiveness of air control devices in indoor environments.
UR - http://www.scopus.com/inward/record.url?scp=77749283343&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77749283343&partnerID=8YFLogxK
U2 - 10.1021/es903437z
DO - 10.1021/es903437z
M3 - Article
C2 - 20143821
AN - SCOPUS:77749283343
SN - 0013-936X
VL - 44
SP - 1742
EP - 1746
JO - Environmental Science and Technology
JF - Environmental Science and Technology
IS - 5
ER -