Abstract
Background: The present study aimed to assess the reliability and reproducibility of coronary computed tomography angiography (CCTA) for the serial quantitative assessment of plaque volume. Methods: Patients who underwent repeated CCTA scans within 90 days were retrospectively screened and enrolled. Clinical data and CCTA imaging data were collected. Paired CCTA scans were analyzed using the quantitative method by separate observers blinded to the other paired CCTA scans. Results were compared between the index CCTA and follow-up CCTA. Results: Paired CT scans of 95 patients (61 ± 13 years; 56.8% men) with same tube voltages (kVp) at both CCTAs and 24 patients (57 ± 19 years; 48.3% men) with different kVp at two CCTAs were analyzed. In patients with same kVp at both CCTAs, there were no difference in PV and PVs of each components in per-segment analysis and per-lesion analysis (all p > 0.05). In per-lesion analysis of CCTAs from patients who used different kVp between two CCTAs, lesion length, area and diameter stenosis, and PVs were not different between index and follow-up CCTAs (all p > 0.05). Segment length and PV were also showed no difference between two serial CCTAs in per-segment analysis. Conclusion: We showed the reproducibility and reliability of quantitative analysis of CCTA for assessment of coronary plaques. CCTA can be applied for the serial quantitative assessment of coronary artery disease progression, regardless of differences in the image acquisition protocol.
Original language | English |
---|---|
Pages (from-to) | 48-54 |
Number of pages | 7 |
Journal | Journal of Cardiovascular Computed Tomography |
Volume | 13 |
Issue number | 1 |
DOIs | |
Publication status | Published - 2019 Jan 1 |
Bibliographical note
Funding Information:This research was supported by Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science and ICT (MSIT) ( 2012027176 ) and also by the Institute for Information & communications Technology Promotion (IITP) grant funded by the Korea government (MSIT) ( 2017-0-00255 , Autonomous digital companion framework and application).
Funding Information:
Dr.Chang receives funds from Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science and ICT (MSIT) (Grant no. 2012027176) and from the Institute for Information and communications Technology Promotion (IITP) grant funded by the MSIT (2017-0-00255). All other authors have nothing to disclose.
Publisher Copyright:
© 2018
All Science Journal Classification (ASJC) codes
- Radiology Nuclear Medicine and imaging
- Cardiology and Cardiovascular Medicine