TY - JOUR
T1 - Comparison of surgically induced astigmatism following iris-claw PIOL insertion with scleral, limbal, or corneal incisions
AU - Kwon, Hee Jung
AU - Nam, Sang Min
AU - Stulting, R. Doyle
AU - Lim, Chan Young
AU - Seo, Kyoung Yul
PY - 2014/5
Y1 - 2014/5
N2 - PURPOSE: To compare surgically induced astigmatism (SIA) based on incision site and evaluate the clinical results and astigmatic stability of iris-claw phakic intraocular lens (Artisan lens; Ophtec BV, Groningen, Netherlands) implantation. METHODS: Eighty-five eyes of 53 patients with myopia who underwent Artisan lens implantation with a 6.2-mm incision and follow-up of 6 months were retrospectively observed. SIA was assessed using keratometric astigmatism at 6 months postoperatively for the incision sites of the sclera, limbus, and cornea, and the efficacy, safety, predictability, and astigmatic stability were also calculated. RESULTS: SIA obtained using Naeser's polar method (KP[90] SIA) was -0.48 ± 0.35 for scleral incisions, -0.99 ± 0.35 for limbal incisions, and -1.14 ± 0.54 for corneal incisions. Corresponding net astigmatism values, as calculated with KP(90)SIA and KP(135)SIA, were 0.70 ± 0.48 (177°), 1.04 ± 0.37 (175°), and 1.21 ± 0.57 (1°), respectively, with SIA increasing the nearer the incision was to the cornea center. Six months after surgery, the efficacy index was 1.03 and the safety index was 1.08. Ninety-eight percent of patients were within 1.50 diopters of attempted refraction. CONCLUSIONS: The values of SIA after Artisan lens insertion showed significant differences among three incision locations, despite the absence of significant differences in preoperative steep corneal axis astigmatism values at the incision locations. It would be applicable for refractive surgery in the aspect of minimizing astigmatism after surgery.
AB - PURPOSE: To compare surgically induced astigmatism (SIA) based on incision site and evaluate the clinical results and astigmatic stability of iris-claw phakic intraocular lens (Artisan lens; Ophtec BV, Groningen, Netherlands) implantation. METHODS: Eighty-five eyes of 53 patients with myopia who underwent Artisan lens implantation with a 6.2-mm incision and follow-up of 6 months were retrospectively observed. SIA was assessed using keratometric astigmatism at 6 months postoperatively for the incision sites of the sclera, limbus, and cornea, and the efficacy, safety, predictability, and astigmatic stability were also calculated. RESULTS: SIA obtained using Naeser's polar method (KP[90] SIA) was -0.48 ± 0.35 for scleral incisions, -0.99 ± 0.35 for limbal incisions, and -1.14 ± 0.54 for corneal incisions. Corresponding net astigmatism values, as calculated with KP(90)SIA and KP(135)SIA, were 0.70 ± 0.48 (177°), 1.04 ± 0.37 (175°), and 1.21 ± 0.57 (1°), respectively, with SIA increasing the nearer the incision was to the cornea center. Six months after surgery, the efficacy index was 1.03 and the safety index was 1.08. Ninety-eight percent of patients were within 1.50 diopters of attempted refraction. CONCLUSIONS: The values of SIA after Artisan lens insertion showed significant differences among three incision locations, despite the absence of significant differences in preoperative steep corneal axis astigmatism values at the incision locations. It would be applicable for refractive surgery in the aspect of minimizing astigmatism after surgery.
UR - http://www.scopus.com/inward/record.url?scp=84901293171&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84901293171&partnerID=8YFLogxK
U2 - 10.3928/1081597X-20140416-02
DO - 10.3928/1081597X-20140416-02
M3 - Article
C2 - 24893358
AN - SCOPUS:84901293171
SN - 1081-597X
VL - 30
SP - 330
EP - 335
JO - Journal of Refractive Surgery
JF - Journal of Refractive Surgery
IS - 5
ER -