TY - JOUR
T1 - Comparison of pulmonary vein isolation using cryoballoon, high-power short-duration, and conventional radiofrequency ablation for atrial fibrillation
T2 - a propensity score-weighted study
AU - Park, Hanjin
AU - Park, Je Wook
AU - Kim, Daehoon
AU - Yu, Hee Tae
AU - Kim, Tae Hoon
AU - Uhm, Jae Sun
AU - Joung, Boyoung
AU - Lee, Moon Hyoung
AU - Hwang, Chun
AU - Pak, Hui Nam
N1 - Publisher Copyright:
2023 Park, Park, Kim, Yu, Kim, Uhm, Joung, Lee, Hwang and Pak.
PY - 2023
Y1 - 2023
N2 - Background: The comparative efficacy, saftey, and heart rate variability (HRV) parameters after pulmonary vein isolation using cryoballoon (Cryo-PVI), high-power short-duration (HPSD-PVI), and conventional radiofrequency ablation (conventional-PVI) for atrial fibrillation (AF) is unclear. Materials and methods: In this propensity score-weighted, retrospective analysis of a single-center cohort, we analyzed 3,395 patients (26.2% female, 74.5% paroxysmal AF) who underwent AF catheter ablation without an empirical left atrial ablation. Procedural factors, recurrence rates, complication rates, and the post-procedural HRV parameters were compared across the Cryo-PVI (n = 625), HPSD-PVI (n = 748), and conventional-PVI (n = 2,022) groups. Results: Despite the shortest procedural time in the Cryo-PVI group (74 min for Cryo-PVI vs. 104 min for HPSD-PVI vs. 153 min for conventional-PVI, p < 0.001), the major complication (p = 0.906) and clinical recurrence rates were similar across the three ablation groups (weighted log-rank, p = 0.824). However, the Cryo-PVI group was associated with a significantly lower risk of recurrent AF in patients with paroxysmal AF [weighted hazard ratio (WHR) 0.57, 95% confidence interval (CI) 0.37–0.86], whereas it was associated with a higher risk of recurrent AF in patients with persistent AF (WHR 1.41, 95% CI 1.06–1.89, p for interaction of <0.001) compared with the conventional-PVI group. In the subgroup analysis for the HRV, the Cryo-PVI group had the highest low-frequency-to-high-frequency ratio at 1-year post-procedure, whereas the HPSD-PVI group had the lowest low-frequency-to-high-frequency ratio at 1-year post-procedure (p < 0.001). Conclusions: The Cryo-PVI group had better rhythm outcomes in patients with paroxysmal AF but worse rhythm outcomes in patients with persistent AF and a higher long-term post-procedural sympathetic nervous activity and sympatho-vagal balance compared with the conventional-PVI group.
AB - Background: The comparative efficacy, saftey, and heart rate variability (HRV) parameters after pulmonary vein isolation using cryoballoon (Cryo-PVI), high-power short-duration (HPSD-PVI), and conventional radiofrequency ablation (conventional-PVI) for atrial fibrillation (AF) is unclear. Materials and methods: In this propensity score-weighted, retrospective analysis of a single-center cohort, we analyzed 3,395 patients (26.2% female, 74.5% paroxysmal AF) who underwent AF catheter ablation without an empirical left atrial ablation. Procedural factors, recurrence rates, complication rates, and the post-procedural HRV parameters were compared across the Cryo-PVI (n = 625), HPSD-PVI (n = 748), and conventional-PVI (n = 2,022) groups. Results: Despite the shortest procedural time in the Cryo-PVI group (74 min for Cryo-PVI vs. 104 min for HPSD-PVI vs. 153 min for conventional-PVI, p < 0.001), the major complication (p = 0.906) and clinical recurrence rates were similar across the three ablation groups (weighted log-rank, p = 0.824). However, the Cryo-PVI group was associated with a significantly lower risk of recurrent AF in patients with paroxysmal AF [weighted hazard ratio (WHR) 0.57, 95% confidence interval (CI) 0.37–0.86], whereas it was associated with a higher risk of recurrent AF in patients with persistent AF (WHR 1.41, 95% CI 1.06–1.89, p for interaction of <0.001) compared with the conventional-PVI group. In the subgroup analysis for the HRV, the Cryo-PVI group had the highest low-frequency-to-high-frequency ratio at 1-year post-procedure, whereas the HPSD-PVI group had the lowest low-frequency-to-high-frequency ratio at 1-year post-procedure (p < 0.001). Conclusions: The Cryo-PVI group had better rhythm outcomes in patients with paroxysmal AF but worse rhythm outcomes in patients with persistent AF and a higher long-term post-procedural sympathetic nervous activity and sympatho-vagal balance compared with the conventional-PVI group.
KW - atrial fibrillation
KW - catheter ablation
KW - cryoballoon ablation
KW - heart rate variability
KW - high-power short-duration ablation
UR - http://www.scopus.com/inward/record.url?scp=85174835265&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85174835265&partnerID=8YFLogxK
U2 - 10.3389/fcvm.2023.1238363
DO - 10.3389/fcvm.2023.1238363
M3 - Article
AN - SCOPUS:85174835265
SN - 2297-055X
VL - 10
JO - Frontiers in Cardiovascular Medicine
JF - Frontiers in Cardiovascular Medicine
M1 - 1238363
ER -