TY - JOUR
T1 - Comparison of peripapillary retinal nerve fiber layer thickness measured by spectral vs. time domain optical coherence tomography
AU - Hong, Samin
AU - Seong, Gong Je
AU - Kim, Sung Soo
AU - Kang, Sung Yong
AU - Kim, Chan Yun
PY - 2011/2
Y1 - 2011/2
N2 - Purpose: To compare the peripapillary retinal nerve fiber layer (RNFL) thickness measured by spectral and time domain optical coherence tomography (OCT). Patients and Methods: One hundred and eighty-eight subjects (normal tension glaucoma, n=80; primary open angle glaucoma, n=49; healthy controls, n=59) were included in this study. Peripapillary RNFL thickness was measured by an Optic Disc Cube 200 × 200 scan of the spectral domain Cirrus HD OCT and by a Fast RNFL scan of the time domain Stratus OCT. They were compared using linear regression (R2), Bland-Altman plots, weighted Kappa (K w) coefficients, and areas under the receiver operating characteristic curve (AROC). Results: Except for the inferior quadrant, RNFL thickness measurements by Cirrus HD OCT were thinner than Stratus OCT (all p < 0.001); for the inferior quadrant, this tendency was vice versa (p = 0.043). Average RNFL thicknesses of the two OCTs showed a good correlation (R2, 0.852) but not excellent agreement (mean of difference, 4.0 μm; +1.96 SD, 10.7 μm; -1.96 SD, -18.6 μm). Regarding the probability codes, only the average RNFL thickness had almost perfect agreement (K w, 0.983). In addition, Cirrus HD OCT had the largest AROC for the superior quadrant (0.795), but Stratus OCT had the largest AROC for average RNFL thickness (0.764) (p = 0.281). Conclusions: Except for the inferior quadrant, the average and quadrants RNFL thickness measured by the Cirrus HD OCT were thinner than the Stratus OCT. Regarding discriminating power for glaucoma detection, the Cirrus HD OCT was better than the Stratus OCT for the superior and inferior quadrant RNFL thicknesses but not for the average RNFL thickness.
AB - Purpose: To compare the peripapillary retinal nerve fiber layer (RNFL) thickness measured by spectral and time domain optical coherence tomography (OCT). Patients and Methods: One hundred and eighty-eight subjects (normal tension glaucoma, n=80; primary open angle glaucoma, n=49; healthy controls, n=59) were included in this study. Peripapillary RNFL thickness was measured by an Optic Disc Cube 200 × 200 scan of the spectral domain Cirrus HD OCT and by a Fast RNFL scan of the time domain Stratus OCT. They were compared using linear regression (R2), Bland-Altman plots, weighted Kappa (K w) coefficients, and areas under the receiver operating characteristic curve (AROC). Results: Except for the inferior quadrant, RNFL thickness measurements by Cirrus HD OCT were thinner than Stratus OCT (all p < 0.001); for the inferior quadrant, this tendency was vice versa (p = 0.043). Average RNFL thicknesses of the two OCTs showed a good correlation (R2, 0.852) but not excellent agreement (mean of difference, 4.0 μm; +1.96 SD, 10.7 μm; -1.96 SD, -18.6 μm). Regarding the probability codes, only the average RNFL thickness had almost perfect agreement (K w, 0.983). In addition, Cirrus HD OCT had the largest AROC for the superior quadrant (0.795), but Stratus OCT had the largest AROC for average RNFL thickness (0.764) (p = 0.281). Conclusions: Except for the inferior quadrant, the average and quadrants RNFL thickness measured by the Cirrus HD OCT were thinner than the Stratus OCT. Regarding discriminating power for glaucoma detection, the Cirrus HD OCT was better than the Stratus OCT for the superior and inferior quadrant RNFL thicknesses but not for the average RNFL thickness.
UR - http://www.scopus.com/inward/record.url?scp=79551529785&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79551529785&partnerID=8YFLogxK
U2 - 10.3109/02713683.2010.533807
DO - 10.3109/02713683.2010.533807
M3 - Article
C2 - 21158587
AN - SCOPUS:79551529785
SN - 0271-3683
VL - 36
SP - 125
EP - 134
JO - Current Eye Research
JF - Current Eye Research
IS - 2
ER -