T1 - Comparison between Ultrasonography and Galactography in Detecting Lesions in Patients with Pathologic Nipple Discharge
AU - Jung, Hyun Kyung
AU - Park, Young Mi
AU - Baek, Hye Jin
AU - Choo, Hye Jung
AU - Kim, Eun Kyung
AU - Kim, Dong Wook
AU - Lee, Sun Joo
AU - Lee, Jin Hwa
N1 - Publisher Copyright:
© 2019 Wolters Kluwer Health, Inc. All rights reserved.
PY - 2019/3/1
Y1 - 2019/3/1
N2 - Purpose This study aimed to compare the diagnostic performance of breast ultrasonography (US) with that of galactography in the detection of lesions in patients with pathologic nipple discharge. Methods We included 46 cases from 39 patients (all women; mean age, 44.0 years; range, 22-68 years) who had pathologic nipple discharge and underwent US and galactography between March 2004 and December 2012. Two radiologists retrospectively reviewed and compared the detectability of lesions on US and galactography images. A receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of US and galactography, and the area under the curve was compared between the 2 imaging modalities. Results A total of 35 cases were pathologically diagnosed. Out of 11 cases that completed a follow-up, none developed malignancies during the follow-up period (mean: 63.5 months; range: 34.8-125.7 months). The sensitivity, specificity, and positive and negative predictive values of US with respect to detectability of lesions were 75%, 42.9%, 11.1%, and 94.7%, respectively, and those of galactography were 100%, 38.1%, 13.3%, and 100%, respectively. Conclusions Galactography is more sensitive than US in the detection of lesions in patients with pathologic nipple discharge.
AB - Purpose This study aimed to compare the diagnostic performance of breast ultrasonography (US) with that of galactography in the detection of lesions in patients with pathologic nipple discharge. Methods We included 46 cases from 39 patients (all women; mean age, 44.0 years; range, 22-68 years) who had pathologic nipple discharge and underwent US and galactography between March 2004 and December 2012. Two radiologists retrospectively reviewed and compared the detectability of lesions on US and galactography images. A receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of US and galactography, and the area under the curve was compared between the 2 imaging modalities. Results A total of 35 cases were pathologically diagnosed. Out of 11 cases that completed a follow-up, none developed malignancies during the follow-up period (mean: 63.5 months; range: 34.8-125.7 months). The sensitivity, specificity, and positive and negative predictive values of US with respect to detectability of lesions were 75%, 42.9%, 11.1%, and 94.7%, respectively, and those of galactography were 100%, 38.1%, 13.3%, and 100%, respectively. Conclusions Galactography is more sensitive than US in the detection of lesions in patients with pathologic nipple discharge.
UR - http://www.scopus.com/inward/record.url?scp=85062525962&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85062525962&partnerID=8YFLogxK
U2 - 10.1097/RUQ.0000000000000365
DO - 10.1097/RUQ.0000000000000365
M3 - Article
C2 - 29768286
AN - SCOPUS:85062525962
SN - 0894-8771
VL - 35
SP - 93
EP - 98
JO - Ultrasound Quarterly
JF - Ultrasound Quarterly
IS - 1
ER -