TY - JOUR
T1 - Clinical Results of Cataract Surgery Using the ARTIS PL e Intraocular Lens
AU - Park, Ella Seo Yeon
AU - Chung, Byung Hoon
AU - Jun, Ikhyun
AU - Kim, Tae Im
AU - Seo, Kyoung Yul
AU - Kim, Eung Kweon
N1 - Publisher Copyright:
© 2022 Korean Ophthalmological Society (KOS). All rights reserved.
PY - 2022/2
Y1 - 2022/2
N2 - Purpose: To compare the clinical outcomes of cataract surgery using the ARTIS PL E (Cristalens Industrie, Lannion, France) intraocular lens (IOL) and conventional Tecnis ZCB00 (Johnson and Johnson Vision, Santa Ana, CA, USA) IOL. Methods: This retrospective study examined patients who underwent in-The-bag implantation of either an ARTIS PL E (33 eyes, group A) or Tecnis ZCB00 (45 eyes, group B) IOL after phacoemulsification performed by a single surgeon. Best-corrected visual acuity (BCVA), spherical equivalent, and higher-order aberrations (HOA) were measured 1 and 3 months after cataract surgery. Results: Preoperative BCVA did not differ significantly in groups A and B. Postoperative BCVA at 1 and 3 months improved significantly (p 0.001) in both groups compared to preoperative baseline BCVA. At 1 and 3 months postoperatively, total HOA, spherical aberration, and coma were significantly lower compared to the preoperative baseline HOA (p 0.05) in both groups. However, there were no significant differences in the trefoil values 1 and 3 months postoperatively compared to the preoperative baseline in both groups. The absolute refractive error 3 months postoperatively was 0.27 ± 0.20 (group A) and 0.28 ± 0.20 (group B), both within ± 0.50 diopters of the targeted goal diopter; there were no significant differences in the accuracy or predictability of the IOL power calculation in both groups (p = 0.390, p = 0.959). The absolute refractive error 1 and 3 months postoperatively did not differ significantly; there were no significant differences in the stability of both IOLs (p = 0.482, p = 0.372). Conclusions: Conventional cataract surgery using the ARTIS PL E IOL significantly increased the BCVA, while obtaining comparable clinical results to the verified Tecnis ZCB00 IOL in postoperative visual acuity and HOA. J Korean Ophthalmol Soc 2022;63(2):134-141.
AB - Purpose: To compare the clinical outcomes of cataract surgery using the ARTIS PL E (Cristalens Industrie, Lannion, France) intraocular lens (IOL) and conventional Tecnis ZCB00 (Johnson and Johnson Vision, Santa Ana, CA, USA) IOL. Methods: This retrospective study examined patients who underwent in-The-bag implantation of either an ARTIS PL E (33 eyes, group A) or Tecnis ZCB00 (45 eyes, group B) IOL after phacoemulsification performed by a single surgeon. Best-corrected visual acuity (BCVA), spherical equivalent, and higher-order aberrations (HOA) were measured 1 and 3 months after cataract surgery. Results: Preoperative BCVA did not differ significantly in groups A and B. Postoperative BCVA at 1 and 3 months improved significantly (p 0.001) in both groups compared to preoperative baseline BCVA. At 1 and 3 months postoperatively, total HOA, spherical aberration, and coma were significantly lower compared to the preoperative baseline HOA (p 0.05) in both groups. However, there were no significant differences in the trefoil values 1 and 3 months postoperatively compared to the preoperative baseline in both groups. The absolute refractive error 3 months postoperatively was 0.27 ± 0.20 (group A) and 0.28 ± 0.20 (group B), both within ± 0.50 diopters of the targeted goal diopter; there were no significant differences in the accuracy or predictability of the IOL power calculation in both groups (p = 0.390, p = 0.959). The absolute refractive error 1 and 3 months postoperatively did not differ significantly; there were no significant differences in the stability of both IOLs (p = 0.482, p = 0.372). Conclusions: Conventional cataract surgery using the ARTIS PL E IOL significantly increased the BCVA, while obtaining comparable clinical results to the verified Tecnis ZCB00 IOL in postoperative visual acuity and HOA. J Korean Ophthalmol Soc 2022;63(2):134-141.
KW - Cataract surgery
KW - Femtosecond laser-Assisted
KW - Higher order aberration
KW - Intraocular lens
KW - Phacoemulsification
UR - http://www.scopus.com/inward/record.url?scp=85125742587&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85125742587&partnerID=8YFLogxK
U2 - 10.3341/jkos.2022.63.2.134
DO - 10.3341/jkos.2022.63.2.134
M3 - Article
AN - SCOPUS:85125742587
SN - 0378-6471
VL - 63
SP - 134
EP - 141
JO - Journal of Korean Ophthalmological Society
JF - Journal of Korean Ophthalmological Society
IS - 2
ER -