Clinical Implications of Device-Detected Atrial Fibrillation in Cardiac Resynchronization Therapy

Minjae Yoon, Jaewon Oh, Kyeong Hyeon Chun, Hee Tae Yu, Chan Joo Lee, Tae Hoon Kim, Hui Nam Pak, Moon Hyoung Lee, Boyoung Joung, Seok Min Kang

Research output: Contribution to journalArticlepeer-review

4 Citations (Scopus)

Abstract

Background and Objectives: Atrial fibrillation (AF) is associated with decreased cardiac resynchronization therapy (CRT) benefits compared to sinus rhythm (SR). Effective biventricular (BiV) pacing is a determinant of CRT success, but AF can interfere with adequate BiV pacing and affect clinical outcomes. We investigated the effect of device-detected AF on clinical outcomes and optimal BiV pacing in patients with heart failure (HF) treated with CRT. Methods: We retrospectively analyzed 174 patients who underwent CRT implantation between 2012 and 2019 at a tertiary center. The optimal BiV pacing percentage was defined as ≥98%. Device-detected AF was defined as an atrial high-rate episode ≥180 beats per minute lasting more than 6 minutes during the follow-up period. We stratified the patients without preexisting AF at pre-implantation into device-detected AF and no-AF groups. Results: A total of 120 patients did not show preexisting AF at pre-implantation, and 54 had AF. Among these 120 patients, 19 (15.8%) showed device-detected AF during a median follow-up of 25.1 months. The proportion of optimal BiV pacing was significantly lower in the device-detected AF group than in the no-AF group (42.1% vs. 75.2%, p=0.009). The device-detected AF group had a higher incidence of HF hospitalization, cardiovascular death, and all-cause death than the no-AF group. The device-detected AF and previous AF groups showed no significant differences regarding the percentage of BiV pacing and clinical outcomes. Conclusions: For HF patients implanted with CRT, device-detected AF was associated with lower optimal BiV pacing and worse clinical outcomes than no-AF.

Original languageEnglish
Article numbere40
JournalKorean Circulation Journal
Volume53
Issue number7
DOIs
Publication statusPublished - 2023 Jul

Bibliographical note

Publisher Copyright:
Copyright © 2023. The Korean Society of Cardiology.

All Science Journal Classification (ASJC) codes

  • Internal Medicine
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Clinical Implications of Device-Detected Atrial Fibrillation in Cardiac Resynchronization Therapy'. Together they form a unique fingerprint.

Cite this