T1 - Changes in posterior corneal elevations after combined transepithelial photorefractive keratectomy and accelerated corneal collagen cross-linking
T2 - Retrospective, comparative observational case series
AU - Lee, Hun
AU - Kang, David Sung Yong
AU - Ha, Byoung Jin
AU - Choi, Jin Young
AU - Kim, Eung Kweon
AU - Seo, Kyoung Yul
AU - Kim, Tae Im
N1 - Publisher Copyright:
© 2016 The Author(s).
PY - 2016/8/8
Y1 - 2016/8/8
N2 - Background: To compare the changes in anterior and posterior corneal elevations after combined transepithelial photorefractive keratectomy (PRK) and accelerated corneal collagen cross-linking (CXL) and after PRK. Methods: Medical records of 82 eyes of 44 patients undergoing either combined transepithelial PRK and CXL (PRK-CXL group) or transepithelial PRK (PRK group) were examined retrospectively. Changes in anterior and posterior corneal elevations were calculated by fitting an 8.0-mm diameter best-fit sphere and best-fit toric ellipsoid (BFTE) to the corneal shape with a fixed eccentricity of 0.4 using Scheimpflug tomography (Pentacam HR; Oculus Optikgeräte GmbH, Wetzlar, Germany) preoperatively and 6 months postoperatively. Results: In anterior corneal elevation, both groups demonstrated a similar trend of a forward displacement of peripheral anterior corneal surface and a backward displacement of central anterior corneal surface. In posterior corneal elevation, a forward displacement of peripheral posterior corneal surface was induced in both groups, along with a backward displacement of central posterior corneal surface, regardless of the calculation method. The magnitudes of displacement of peripheral and central posterior corneal surfaces were significantly smaller in the PRK-CXL group than in the PRK group. Moreover, the PRK-CXL group showed a backward displacement of posterior corneal surface at maximum corneal elevations when the BFTE was used as the reference surface. Conclusions: Transepithelial PRK combined with prophylactic CXL significantly reduced the magnitudes of displacement of peripheral and central posterior corneal surfaces, with the radius of the BFTE was set to 8.0-mm on the Scheimpflug tomography system.
AB - Background: To compare the changes in anterior and posterior corneal elevations after combined transepithelial photorefractive keratectomy (PRK) and accelerated corneal collagen cross-linking (CXL) and after PRK. Methods: Medical records of 82 eyes of 44 patients undergoing either combined transepithelial PRK and CXL (PRK-CXL group) or transepithelial PRK (PRK group) were examined retrospectively. Changes in anterior and posterior corneal elevations were calculated by fitting an 8.0-mm diameter best-fit sphere and best-fit toric ellipsoid (BFTE) to the corneal shape with a fixed eccentricity of 0.4 using Scheimpflug tomography (Pentacam HR; Oculus Optikgeräte GmbH, Wetzlar, Germany) preoperatively and 6 months postoperatively. Results: In anterior corneal elevation, both groups demonstrated a similar trend of a forward displacement of peripheral anterior corneal surface and a backward displacement of central anterior corneal surface. In posterior corneal elevation, a forward displacement of peripheral posterior corneal surface was induced in both groups, along with a backward displacement of central posterior corneal surface, regardless of the calculation method. The magnitudes of displacement of peripheral and central posterior corneal surfaces were significantly smaller in the PRK-CXL group than in the PRK group. Moreover, the PRK-CXL group showed a backward displacement of posterior corneal surface at maximum corneal elevations when the BFTE was used as the reference surface. Conclusions: Transepithelial PRK combined with prophylactic CXL significantly reduced the magnitudes of displacement of peripheral and central posterior corneal surfaces, with the radius of the BFTE was set to 8.0-mm on the Scheimpflug tomography system.
UR - http://www.scopus.com/inward/record.url?scp=84985011739&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84985011739&partnerID=8YFLogxK
U2 - 10.1186/s12886-016-0320-3
DO - 10.1186/s12886-016-0320-3
M3 - Article
C2 - 27502494
AN - SCOPUS:84985011739
SN - 1471-2415
VL - 16
JO - BMC Ophthalmology
JF - BMC Ophthalmology
IS - 1
M1 - 139
ER -