Abstract
Purpose: To calculate actual corneal astigmatism using the total corneal refractive astigmatism for the 4-mm apex zone of the Pentacam (TCRP4astig) and keratometric astigmatism (Kastig) before and after photorefractive keratectomy or laser in situ keratomileusis Methods: Uncomplicated 56 eyes after more than 6 months from the surgery were recruited by chart review. Various corneal astigmatisms were measured using the Pentacam and autokeratometer before and after surgery. Three eyes were excluded and 53 eyes of 38 subjects with with-the-rule astigmatism (WTR) were finally included. The astigmatisms were investigated using polar value analysis. When TCRP4astig was set as an actual astigmatism, the efficacy of arithmetic or coefficient adjustment of Kastig was evaluated using bivariate analysis. Results: The difference between the simulated keratometer astigmatism of the Pentacam (SimKastig) and Kastig was strongly correlated with the difference between TCRP4astig and Kastig. TCRP4astig was different from Kastig in magnitude rather than meridian before and after surgery; the preoperative difference was due to the posterior cornea only; however, the postoperative difference was observed in both anterior and posterior parts. For arithmetic adjustment, 0.28 D and 0.27 D were subtracted from the preoperative and postoperative magnitudes of Kastig, respectively. For coefficient adjustment, the preoperative and postoperative magnitudes of Kastig were multiplied by 0.80 and 0.66, respectively. By arithmetic or coefficient adjustment, the difference between TCRP4astig and adjusted Kastig would be less than 0.75 D in magnitude for 95% of cases. Conclusions: Kastig was successfully adjusted to TCPR4astig before and after myopic keratorefractive surgery in cases of WTR. For use of TCRP4astig directly, SimKastig and Kastig should be matched.
Original language | English |
---|---|
Article number | e0175268 |
Journal | PloS one |
Volume | 12 |
Issue number | 4 |
DOIs | |
Publication status | Published - 2017 Apr |
Bibliographical note
Funding Information:The Pentacam was operated in 25-image mode, in which the rotating camera acquires 25 scans within 2 s. Every Pentacam in this study was calibrated and technically supported by the manufacturer. Several types of corneal astigmatism were detected, as described below and in .
Publisher Copyright:
© 2017 Seo et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
All Science Journal Classification (ASJC) codes
- Biochemistry, Genetics and Molecular Biology(all)
- Agricultural and Biological Sciences(all)
- General