TY - JOUR
T1 - Biologic evaluation of a hollow-type miniscrew implant
T2 - An experimental study in beagles
AU - Youn, Jeong Won
AU - Cha, Jung Yul
AU - Yu, Hyung Seog
AU - Hwang, Chung Ju
PY - 2014/5
Y1 - 2014/5
N2 - Introduction The aims of this study were to assess the biologic stability of a newly designed hollow (H-type) miniscrew compared with conventional (C-type) miniscrews through histomorphometric and histologic analysis. Methods Both types of miniscrews were placed into the maxillae and the mandibles of 12 beagles. Maximum insertion torque, Periotest (Siemens AG, Bensheim, Germany) value, bone-implant contact, and bone volume were measured. Results The overall success rates of the H-type were 78.3% in the maxilla and 60.0% in the mandible. Mean maximum insertion torque values of the H-type were 14.2 N-cm in the maxilla and 20.9 N-cm in the mandible. The Periotest values of the H-type were -1.5 in the maxilla and -6.4 in the mandible. Mean maximum insertion torque and Periotest values of the H-type were higher than those of the C-type. In the maxilla, the bone-implant contact values of the H-type were 37.3% and 32.3% at 3 and 12 weeks, respectively. In the mandible, the bone-implant contact values were 31.4% and 18.5% at 3 and 12 weeks, respectively. Conclusions Considering the lower success rate and the insufficient bone-implant contact and bone volume of the H-type in the mandible, the clinician should choose a suitable combination of miniscrews depending on local bone quality and implantation site, such as an H-type in the maxilla and a C-type in the mandible.
AB - Introduction The aims of this study were to assess the biologic stability of a newly designed hollow (H-type) miniscrew compared with conventional (C-type) miniscrews through histomorphometric and histologic analysis. Methods Both types of miniscrews were placed into the maxillae and the mandibles of 12 beagles. Maximum insertion torque, Periotest (Siemens AG, Bensheim, Germany) value, bone-implant contact, and bone volume were measured. Results The overall success rates of the H-type were 78.3% in the maxilla and 60.0% in the mandible. Mean maximum insertion torque values of the H-type were 14.2 N-cm in the maxilla and 20.9 N-cm in the mandible. The Periotest values of the H-type were -1.5 in the maxilla and -6.4 in the mandible. Mean maximum insertion torque and Periotest values of the H-type were higher than those of the C-type. In the maxilla, the bone-implant contact values of the H-type were 37.3% and 32.3% at 3 and 12 weeks, respectively. In the mandible, the bone-implant contact values were 31.4% and 18.5% at 3 and 12 weeks, respectively. Conclusions Considering the lower success rate and the insufficient bone-implant contact and bone volume of the H-type in the mandible, the clinician should choose a suitable combination of miniscrews depending on local bone quality and implantation site, such as an H-type in the maxilla and a C-type in the mandible.
UR - http://www.scopus.com/inward/record.url?scp=84899767849&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84899767849&partnerID=8YFLogxK
U2 - 10.1016/j.ajodo.2013.12.028
DO - 10.1016/j.ajodo.2013.12.028
M3 - Article
C2 - 24785927
AN - SCOPUS:84899767849
SN - 0889-5406
VL - 145
SP - 626
EP - 637
JO - American Journal of Orthodontics and Dentofacial Orthopedics
JF - American Journal of Orthodontics and Dentofacial Orthopedics
IS - 5
ER -