Abstract
Abstract This study was an experimental investigation of the effect of an intersecting rib on heat/mass transfer performance in rectangular channels with angled ribs and different aspect ratios. In a rib-roughened channel with angled ribs, heat/mass transfer performance deteriorates as the channel aspect ratio increases, since the vortices induced by angled ribs diminish with increasing aspect ratio. A longitudinal rib that bisects the angled ribs is suggested to overcome this disadvantage. The heat transfer performance of angled rib configurations with a 60° attack angle were tested with and without an intersecting rib using naphthalene sublimation method. The channel aspect ratio is varied from 1 to 4. When the intersecting rib was present, additional vortices were generated at every point of intersection with the angled ribs. Thus the heat/mass transfer performance was significantly enhanced for all channel aspect ratios when an intersecting rib was added to an ordinary angled rib configuration.
Original language | English |
---|---|
Article number | 11928 |
Pages (from-to) | 357-367 |
Number of pages | 11 |
Journal | International Journal of Heat and Mass Transfer |
Volume | 88 |
DOIs | |
Publication status | Published - 2015 Sept 1 |
Bibliographical note
Publisher Copyright:© 2015 Elsevier Ltd. All rights reserved.
All Science Journal Classification (ASJC) codes
- Condensed Matter Physics
- Mechanical Engineering
- Fluid Flow and Transfer Processes