TY - JOUR
T1 - Assessment of Device Neoendothelialization With Cardiac Computed Tomography Angiography After Transcatheter Closure of Atrial Septal Defect
AU - Kim, Ah Young
AU - Woo, Wongi
AU - Lim, Beom Jin
AU - Jung, Jo Won
AU - Choi, Jae Young
AU - Kim, Young Jin
N1 - Publisher Copyright:
© 2021 American Heart Association, Inc.
PY - 2022/7/1
Y1 - 2022/7/1
N2 - Background: Although the transcatheter closure of atrial septal defect was established as the treatment of choice several decades ago, the process of device neoendothelialization (NE) in humans is not well understood. We aimed to measure the extent of device NE using cardiac computed tomography angiography and analyze its risk factors. Methods: Between January 2005 and February 2021, we retrospectively reviewed 164 devices of 112 patients on cardiac computed tomography angiography. We investigated device shape, contrast opacification within the device that differentiated device NE, and device-related thrombosis or vegetation. Risk factor analysis for major adverse cardiovascular events and incomplete NE according to the postprocedural period was performed. Results: Seventy patients (62.5%) were women, with a median (range) age at the time of device closure of 44.5 (0.6-79.2) years. The mean (±SD) defect size was 16.6 (±7.8) mm, and patients were followed for 35.9±33.9 months. After 6 months of device implantation, 35% of the devices (42/120) had incomplete NE. The intensity of intradevice opacification shifted from complete to partial or nonopacification over time (P<0.001), and a similar pattern was observed in the shunt flow (P<0.001). The bulkiness of devices also decreased in proportion to the postprocedural period (P<0.001). Risk analysis revealed device diameter (hazard ratio, 1.18 [95% CI, 1.04-1.27]; P<0.001) as the only significant factor of incomplete NE and major adverse events. Conclusions: Incomplete NE of atrial septal defect devices was identified on cardiac computed tomography angiography in significant numbers after 6 months of the procedure. The device diameter was related to incomplete NE and major adverse events. Further prospective and multicenter studies are warranted to validate this new assessment of device NE.
AB - Background: Although the transcatheter closure of atrial septal defect was established as the treatment of choice several decades ago, the process of device neoendothelialization (NE) in humans is not well understood. We aimed to measure the extent of device NE using cardiac computed tomography angiography and analyze its risk factors. Methods: Between January 2005 and February 2021, we retrospectively reviewed 164 devices of 112 patients on cardiac computed tomography angiography. We investigated device shape, contrast opacification within the device that differentiated device NE, and device-related thrombosis or vegetation. Risk factor analysis for major adverse cardiovascular events and incomplete NE according to the postprocedural period was performed. Results: Seventy patients (62.5%) were women, with a median (range) age at the time of device closure of 44.5 (0.6-79.2) years. The mean (±SD) defect size was 16.6 (±7.8) mm, and patients were followed for 35.9±33.9 months. After 6 months of device implantation, 35% of the devices (42/120) had incomplete NE. The intensity of intradevice opacification shifted from complete to partial or nonopacification over time (P<0.001), and a similar pattern was observed in the shunt flow (P<0.001). The bulkiness of devices also decreased in proportion to the postprocedural period (P<0.001). Risk analysis revealed device diameter (hazard ratio, 1.18 [95% CI, 1.04-1.27]; P<0.001) as the only significant factor of incomplete NE and major adverse events. Conclusions: Incomplete NE of atrial septal defect devices was identified on cardiac computed tomography angiography in significant numbers after 6 months of the procedure. The device diameter was related to incomplete NE and major adverse events. Further prospective and multicenter studies are warranted to validate this new assessment of device NE.
KW - computed tomography angiography
KW - heart septal defects, atrial
KW - prostheses and implants
KW - risk factors
KW - thrombosis
UR - http://www.scopus.com/inward/record.url?scp=85134855176&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85134855176&partnerID=8YFLogxK
U2 - 10.1161/CIRCIMAGING.122.014138
DO - 10.1161/CIRCIMAGING.122.014138
M3 - Article
C2 - 35861980
AN - SCOPUS:85134855176
SN - 1941-9651
VL - 15
SP - E014138
JO - Circulation: Cardiovascular Imaging
JF - Circulation: Cardiovascular Imaging
IS - 7
ER -