TY - JOUR
T1 - A study on the measurement of heart rate variability using the modified laplacian electrodes
AU - Lee, Chung Keun
AU - Shin, Hang Sik
AU - Kim, Hong Rae
AU - Lee, Jeong Whan
AU - Kim, Yong Jun
AU - Lee, Myoung Ho
PY - 2009/5
Y1 - 2009/5
N2 - Heart Rate Variability(HRV) is a parameter that represents monitoring variability of time intervals between R-peak in electrocardiography. HRV serves to various applications, such as indices of autonomic functions, prediction of cardiac sudden death, assessment of stress and emotional, etc. However, as measuring R-peak in ECG needs at least 3-electrodes, and it is inconvenient for end users. In this paper, we suggested the modified laplacian electrodes for measuring HRV at one-point, which are producted by MEMS fabrication and have the two circular electrodes on the pad. For optimal position and direction, we performed an experiment that compared with pearson correlation coefficient and the amplitude of signals, between standard lead II and proposed electrodes. We analyzed the HRV parameters, such as standard deviation of the NN interval(SDNN), high frequency(HF), low frequency(LF), LF/HF ratio. The result showed that the average correlation coefficient and amplitude are 0.967 and 0.685 mVpp at the position 2. The coeffiecient correlation between the standard HRV and proposed electrode-HRV is 0.999.
AB - Heart Rate Variability(HRV) is a parameter that represents monitoring variability of time intervals between R-peak in electrocardiography. HRV serves to various applications, such as indices of autonomic functions, prediction of cardiac sudden death, assessment of stress and emotional, etc. However, as measuring R-peak in ECG needs at least 3-electrodes, and it is inconvenient for end users. In this paper, we suggested the modified laplacian electrodes for measuring HRV at one-point, which are producted by MEMS fabrication and have the two circular electrodes on the pad. For optimal position and direction, we performed an experiment that compared with pearson correlation coefficient and the amplitude of signals, between standard lead II and proposed electrodes. We analyzed the HRV parameters, such as standard deviation of the NN interval(SDNN), high frequency(HF), low frequency(LF), LF/HF ratio. The result showed that the average correlation coefficient and amplitude are 0.967 and 0.685 mVpp at the position 2. The coeffiecient correlation between the standard HRV and proposed electrode-HRV is 0.999.
UR - http://www.scopus.com/inward/record.url?scp=67649522471&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=67649522471&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:67649522471
SN - 1975-8359
VL - 58
SP - 1050
EP - 1056
JO - Transactions of the Korean Institute of Electrical Engineers
JF - Transactions of the Korean Institute of Electrical Engineers
IS - 5
ER -