TY - JOUR
T1 - A self-powered one-touch blood extraction system
T2 - A novel polymer-capped hollow microneedle integrated with a pre-vacuum actuator
AU - Li, Cheng Guo
AU - Dangol, Manita
AU - Lee, Chang Yeol
AU - Jang, Mingyu
AU - Jung, Hyungil
N1 - Publisher Copyright:
© The Royal Society of Chemistry 2015.
PY - 2015/1/21
Y1 - 2015/1/21
N2 - Blood is the gold standard sample medium that can provide a wide variety of useful biological information for the diagnosis of various diseases. For portable point-of-care diagnosis, blood extraction systems have attracted attention as easier, safer, and more rapid methods of collecting small blood volumes. In this paper, we introduce a novel self-powered one-touch blood extraction system created by assembling a smart polymer-capped hollow microneedle in a pre-vacuum polydimethylsiloxane actuator. The optimized hollow microneedle was precisely fabricated by drawing lithography for minimally invasive blood extraction, with a length of 1800 μm, an inner diameter of 60 μm, an outer diameter of 130 μm, and a bevel angle of 15°. The system utilizes only a single step for operation; a finger press activates the blood sampling process based on the negative pressure-driven force built into the pre-vacuum activated actuator. A sufficient volume of blood (31.3 ± 2.0 μl) was successfully extracted from a rabbit for evaluation using a micro total analysis system. The entire system was made of low-cost and disposable materials to achieve easy operation with a miniature structure and to meet the challenging requirements for single-use application in a point-of-care system without the use of any external power equipment.
AB - Blood is the gold standard sample medium that can provide a wide variety of useful biological information for the diagnosis of various diseases. For portable point-of-care diagnosis, blood extraction systems have attracted attention as easier, safer, and more rapid methods of collecting small blood volumes. In this paper, we introduce a novel self-powered one-touch blood extraction system created by assembling a smart polymer-capped hollow microneedle in a pre-vacuum polydimethylsiloxane actuator. The optimized hollow microneedle was precisely fabricated by drawing lithography for minimally invasive blood extraction, with a length of 1800 μm, an inner diameter of 60 μm, an outer diameter of 130 μm, and a bevel angle of 15°. The system utilizes only a single step for operation; a finger press activates the blood sampling process based on the negative pressure-driven force built into the pre-vacuum activated actuator. A sufficient volume of blood (31.3 ± 2.0 μl) was successfully extracted from a rabbit for evaluation using a micro total analysis system. The entire system was made of low-cost and disposable materials to achieve easy operation with a miniature structure and to meet the challenging requirements for single-use application in a point-of-care system without the use of any external power equipment.
UR - http://www.scopus.com/inward/record.url?scp=84918775499&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84918775499&partnerID=8YFLogxK
U2 - 10.1039/c4lc00937a
DO - 10.1039/c4lc00937a
M3 - Article
C2 - 25352059
AN - SCOPUS:84918775499
SN - 1473-0197
VL - 15
SP - 382
EP - 390
JO - Lab on a Chip - Miniaturisation for Chemistry and Biology
JF - Lab on a Chip - Miniaturisation for Chemistry and Biology
IS - 2
ER -