TY - JOUR
T1 - A Comparative Study of Two Extended Depth of Focus Intraocular Lenses
AU - Song, Mi Yeon
AU - Kang, Kyoung Hae
AU - Lee, Hun
AU - Kim, Tae Im
AU - Koh, Kyungmin
N1 - Publisher Copyright:
© 2022 Lippincott Williams and Wilkins. All rights reserved.
PY - 2022/10/1
Y1 - 2022/10/1
N2 - Objective:To assess and compare the visual performance of two extended depth-of-focus intraocular lenses (IOLs), Tecnis Symfony (Symfony; Johnson & Johnson Vision, Santa Ana, CA) and Acrysof IQ Vivity (Vivity; Alcon Inc, Fort Worth, TX).Methods:The medical records of patients undergoing cataract surgery with Symfony or Vivity implantation from May 2021 to September 2021 and the data available for the 3-month follow-up were reviewed. The main measures of the findings were uncorrected and corrected distance (4 m) visual acuity (VA), uncorrected intermediate (66 cm) VA (UIVA) and uncorrected near (40 and 33 cm) VA (UNVA), refractive error (RE), defocus profiles analysis, optical quality parameters, and patient-reported quality of vision questionnaire results.Results:Of the 40 patients, 19 patients (31 eyes) were treated with the Symfony IOL and 21 (32 eyes) with the Vivity IOL. The mean age of the patients was 63.4±7.8 (range, 40-76) years in the Symfony group and 61.8±9.7 (range, 40-77) years in the Vivity group. There was no meaningful difference between the two groups in the preoperative parameters, except that the Vivity group had a better CDVA. Among the main measures of results, there was no statistically significant difference, except for the UNVA (33 cm). The Symfony group also showed a smoother defocus curve at 3 months postoperatively.Conclusion:There was no significant difference between the two groups regarding uncorrected/corrected distance VA, UIVA, UNVA (40 cm), RE, optical quality parameters, and patient-reported quality of vision questionnaire results. The Symfony group demonstrated a significantly superior UNVA (33 cm) and a smoother defocus curve with a broad landing zone.
AB - Objective:To assess and compare the visual performance of two extended depth-of-focus intraocular lenses (IOLs), Tecnis Symfony (Symfony; Johnson & Johnson Vision, Santa Ana, CA) and Acrysof IQ Vivity (Vivity; Alcon Inc, Fort Worth, TX).Methods:The medical records of patients undergoing cataract surgery with Symfony or Vivity implantation from May 2021 to September 2021 and the data available for the 3-month follow-up were reviewed. The main measures of the findings were uncorrected and corrected distance (4 m) visual acuity (VA), uncorrected intermediate (66 cm) VA (UIVA) and uncorrected near (40 and 33 cm) VA (UNVA), refractive error (RE), defocus profiles analysis, optical quality parameters, and patient-reported quality of vision questionnaire results.Results:Of the 40 patients, 19 patients (31 eyes) were treated with the Symfony IOL and 21 (32 eyes) with the Vivity IOL. The mean age of the patients was 63.4±7.8 (range, 40-76) years in the Symfony group and 61.8±9.7 (range, 40-77) years in the Vivity group. There was no meaningful difference between the two groups in the preoperative parameters, except that the Vivity group had a better CDVA. Among the main measures of results, there was no statistically significant difference, except for the UNVA (33 cm). The Symfony group also showed a smoother defocus curve at 3 months postoperatively.Conclusion:There was no significant difference between the two groups regarding uncorrected/corrected distance VA, UIVA, UNVA (40 cm), RE, optical quality parameters, and patient-reported quality of vision questionnaire results. The Symfony group demonstrated a significantly superior UNVA (33 cm) and a smoother defocus curve with a broad landing zone.
KW - Defocus curve
KW - Extended depth of focus
KW - Intraocular lens
KW - Presbyopia
KW - Presbyopia-correcting intraocular lens
UR - http://www.scopus.com/inward/record.url?scp=85138622571&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85138622571&partnerID=8YFLogxK
U2 - 10.1097/ICL.0000000000000931
DO - 10.1097/ICL.0000000000000931
M3 - Article
C2 - 36155949
AN - SCOPUS:85138622571
SN - 1542-2321
VL - 48
SP - 433
EP - 438
JO - Eye and Contact Lens
JF - Eye and Contact Lens
IS - 10
ER -